| 1 | 强化传热的场协同理论研究进展显示文摘概述了场协同原理的研究进展,从理论角度分析了速度场与温度梯度场协同程度的改变会影响强化传热的效果,阐述了验证场协同原理的两种方法和场协同原理在实际中的应用。由唯象理论导出了多场协同与强化换热的关系,概述了多场协同强化换热的研究进展。 | 熊少武 罗小平 高贵良 | 2007 | 石油化工设备2007,36,1: | 12 |
| 2 | 电场强化乙醚自然对流和池沸腾换热显示文摘The electric field enhancement of natural convection and pool boiling heat transfer on a plate surface immersed in ether was investigated.The experimental data indicated that electric field could enhance natural convection and pool boiling heat transfer.The enhancement effect of electric field on natural convection heat transfer was larger than the effect on pool boiling heat transfer.For natural convection heat transfer on plate surface immersed in ether,the enhancement effect of electric field gradually increased as voltage rose and decreased with increasing heat flux.For pool boiling heat transfer on plate surface immersed in ether, the enhancement effect of electric field gradually increased as voltage rose at heat flux q=5—9 kW·m-2.At the other testing heat flux(q≥10 kW·m-2), the increase of pool boiling heat transfer coefficient by applying electric field was much less.In the experimental condition, the enhancement effect of electric field on pool boiling heat transfer decreased with increasing heat flux. | 王发刚 李瑞阳 郁鸿凌 刘永启 柳玉英 | 2005 | 化工学报2005,56,11: | 4 |
| 3 | 以水为工质的EHD强化管内对流换热实验研究显示文摘以水作为工质,实验研究了EHD(Electrohydrodynamics)对水套管式换热器内对流换热过程的强化作用机理。实验中,在水套管换热器换热管中心设置一直流式高压电极,电极电压DC设置范围为0~40 kV,分别进行了5组不同流量下不同电压值的组合强化实验。实验结果表明:不同管内流量条件下电场对管内传热过程均有不同程度的强化作用,当流量为0.1 m3/h时,其电场强化系数θ最大,为1.224;流量为1.0 m3/h时,电场强化系数θ最小。实验证实了电场对于以水为工质的对流传热过程具有强化作用,但电场强化效果具有对流量变化敏感性的特点,同流量下存在最佳强化电压值而非电压值越高强化效果越大。 | 杨侠 张捷 吴艳阳 张涛 | 2011 | 热能动力工程2011,26,5: | 3 |
| 4 | 电场强化夹套间不同构造管对流传热研究显示文摘文中以空气为工质,对水平光管、横纹管、花瓣管在夹套间的强制对流传热进行了高压电场强化(EHD效应)实验研究,揭示了EHD在强化对流传热上的一些基本规律。实验结果表明,外加高压电场对强化对流传热有较好的综合效果,在Re=5000,电极电压为30 kV的实验条件下,花瓣管、横纹管和光管的最大强化率依次为2.76,1.75和1.36。根据光管的实验结果,对有、无电场作用下的压力波动进行了时间序列分析,得出了Lyapunov指数,并从动力学角度分析了EHD效应对强化传热的影响。 | 陈志静 罗小平 高贵良 | 2009 | 化学工程2009,37,2: | 2 |
| 5 | Experimental Study on Convective Heat Transfer in Tube-Side of Water Jacket-Tube Heat Exchanger by Electrohydrodynamics Effect显示文摘The electrohydrodynamics (EHD) enhancement of convection heat transfer of water in a jacket tube heat exchanger was studied through an experimental method in this paper. In the experiment,a DC high voltage electrode was set in the central tube-side of the heat exchanger,and the high voltage electrode in the tube-side was adjustable in the range of 0-40 kV. Five differ-ent combinations of heat transfer enhancement experiments were conducted under the different voltage and rate of flow. The results indicate that the maximal enhancement coefficient θ is 1.224 when the flow rate of tube-side inlet is 0.1 m3/h. It is proved that,for the work medium of water,the convective heat transfer can be enhanced by applying high electric field. The performance of EHD-enhanced is sensitive to the variation of flow rate,and in the same flow rate,there exist an optimized voltage in the EHD-enhanced process ra-ther than the monotonic positive-correlation relationship. | YANG Xia ZHANG Jie WU Yanyang ZHANG Tao MAO Zhihui | 2011 | Wuhan University Journal of Natural Sciences2011,16,1: | 2 |
| 6 | 几种换热管在电场强化对流实验中传热性能比较显示文摘对水平光管、横纹管、螺旋槽管、花瓣管在电场强化(EHD)单管试验中进行对流传热实验,蒸汽走管程,空气走壳程。实验结果表明:在相同的雷诺数下,施加电场后,传热膜系数和阻力系数都有一定的提高,其中花瓣管的强化效率指标最大,达到1.98,在电压为30 kV时,花瓣管外电场强化作用最明显,强化系数达2.76。 | 罗小平 王青松 | 2009 | 炼油技术与工程2009,39,8: | 1 |
| 7 | 电场作用下电对流强化换热现象研究显示文摘为了揭示电场对自然对流换热的影响,采用高速摄影技术对R113工质在自然对流区的电对流强化换热现象进行了实验研究,高压电源1~5 kV、热流密度4.46~17.80 kW/m^2,分析了电对流层高度、加热面温度、对流换热系数以及电场的强化换热系数的动态变化规律。实验发现:施加电场后,在加热面上方形成了稳定的电对流层,电对流层高度随着施加电压的升高而逐渐减小,由于电场增强流体的扰动,使得壁面温度降低,进而强化了换热,实验中强化换热系数可达1.2倍。 | 高明 张凌霜 张达 章立新 | 2020 | 热能动力工程2020,35,1: | 1 |
| 8 | 高压电场强化空气对流传热实验及其数值模拟显示文摘以空气为实验介质,对水平光管、横纹管、缩放管和螺旋槽管的强制对流传热进行了高压电场强化实验,研究了高压电场强化传热的一些基本规律。实验验证了当外加高压大于15 kV后,对强制对流传热有较好的综合传热效果,最大强化率达2.8,而阻力系数的增大倍数在1.5—1.9。并对横纹管进行了数值模拟,从场协同的角度研究了速度场与温度场夹角对传热膜系数的影响。结果表明,速度、温度梯度的大小,及两者夹角的余弦值均会影响传热效果,在三者的值都是最大的位置,其传热膜系数也最大。 | 罗小平 高贵良 方振鑫 | 2008 | 化学工程2008,36,5: | 0 |
| 9 | 以水为工质的EHD与脉动流混合强化对流传热数值研究显示文摘对EHD及脉动流在换热圆管中的混合作用进行了数值模拟。模拟结果表明,EHD与脉动流对对流换热具有一定的复合强化作用,无电场情况下,脉动流单独作用对圆管中的对流换热没有明显的影响,加入电场后,脉动流能够在EHD强化换热的基础上提供额外的传热增益,对流传热系数增益幅度在2.7%左右,增益效果受脉动幅度影响显著,但几乎不受脉动频率的影响。 | 杨侠 毛志慧 吴艳阳 张涛 | 2011 | 石油和化工设备2011,14,11: | 0 |