多次雷电冲击对氧化锌避雷器阀片性能的影响(英文)

查看全文 作  者:Haryono [1]T;Sirait K [2]T;[1]Tumiran;Hamzah [1]Berahim 高影响力作者 机构地区:[1]Electrical Engineering and Information Technology Department,Universitas Gadjah Mada,Yogyakarta,Indonesia;[2]School of Electrical Engineering and Information Technology,Bandung,Indonesia高影响力机构 出  处:《高电压技术》索引2011年第37卷第11期,共9页高影响力期刊 摘  要:A lightning arrester is used for electrical equipment protection against damage due to lightning strikes.One example of protected electrical equipment is electrical power transformer.If there is no lightning arrester installed to the transformer,when a lightning strike happens,it may receive a very high lightning overvoltage,which is certainly resulted in the transformer damage at its insulation.Usually,a lightning arrester specification data attached to a lightning arrester contains the rating data of the lightning arrester current and voltage.In the use of lightning arrester,the possibility of receiving multiple lightning strikes is not taken into account sometimes.In fact,in some places,the number of multiple strikes in short duration is quiet high in number.This condition makes the lightning arrester being stroked by multiple lightning strikes.Therefore,it may change the lightning arrester's properties,and then the arrester may not be able to provide good electrical equipment protection against lightning strike anymore.This condition will result in great loss to electrical companies and electrical consumers.Therefore,this research studied the effect of applying multiple lightning strikes to ZnO lightning arrester block.Every time a group of lightning impulse current is applied to the ZnO lightning arrester block,it is followed by the measuring of its 50 Hz voltage and current characteristic. The changing in the ZnO lightning arrester block 50 Hz characteristic then can be analyzed.It was found that by applying more numbers of lightning strikes which made the arrester becoming worse,even though,actually,the lightning impulse peak current was still under the rating of the lightning arrester current.In this case for a 5 kA,24 kV lightning arrester,even though the lightning impulse peak current flowing through the ZnO lightning arrester block was still 2500 A,the lightning arrester ZnO block had already been damaged.Having been damaged,an alternating current flowing through the damaged ZnO block was about 10000 times as much current flowing to the good one.The maximum of impulse energy absorbed by a ZnO block recorded was 334.7 J/cm^3.The damaged ZnO block should be replaced by a good one. 关 键 词:follow current impulse current lightning arrester lightning strike multiple impulse current ZnO block
相关文献

参考文献(23)

引证文献(18)

网站首页 | 关于我们 | 联系我们 | 产品服务 | 客服中心 | 广告服务 | 版权声明 | 网站联盟 | 友情链接 | 售卡网点

版权所有© 渝B2-20050021-1 渝公网安备 50019002500403号 违法和不良信息举报中心

互联网出版许可证 新出网证(渝)字10号 全国400电话 - 免长途话费