A data-driven model predictive control for lighting system based on historical occupancy in an office building: Methodology development

查看全文 作  者:Yuan [1]Jin;Da [1]Yan;Xingxing [2]Zhang;Jingjing [1]An;Mengjie [2]Han 高影响力作者 机构地区:[1]School of Architecture,Tsinghua University,Beijing,100084,China;[2]School of Industrial Technology and Business Studies,Dalarna University,Falun,79188,Sweden高影响力机构 出  处:《Building Simulation》索引2021年第14卷第1期,共17页高影响力期刊 基  金:This study was supported by the National Natural Science Foundation of China(No.51778321):Research on the quantitative description and simulation methodology of occupant behavior in buildings;the Innovative Research Groups of the National Natural Science Foundation of China(No.51521005);also the Tsinghua University tutor research fund. 摘  要:The lighting system accounts for 8%of the total electricity consumption in commercial buildings in the United States and 12%of the total electricity consumption in public buildings globally.This consumption share can be effectively reduced using the demand-response control.The traditional lighting system control method commonly depends on the real-time occupancy data collected using the passive infrared(PIR)sensor.However,the detection inaccuracy of the PIR sensor usually results in false-offs.To diminish the false-error frequency,the existing lighting system control simply deploys a delayed reaction period(e.g.,5 to 20 min),which is not sufficiently accurate for the demand-response operation.Therefore,in this research,a novel data-driven model predictive control(MPC)method that is based on the temporal sequential-based artificial neural network(TS-ANN)is proposed to overcome this challenge using an updated historical occupancy status.Using an office as case study,the proposed model is also compared with the traditional lighting system control method.In the proposed model,the occupancy data was trained to predict the occupancy pattern to improve the control.It was found that the occupancy prediction mainly correlates with the historical occupancy ratio and the time sequential feature.The simulation results indicated that the proposed method achieved higher accuracy(97.4%)and fewer false-offs(from 79.5 with traditional time delay method to 0.6 times per day)are achieved by the MPC model.The proposed TS-ANN-MPC method integrates the analysis of the occupant behavior routine into on-site control and has the potential to further enhance the control performance practice for maximum energy conservation. 关 键 词:lighting system occupant behavior DATA-DRIVEN model predictive control
相关文献

参考文献(56)

引证文献(10)

耦合文献(20)

网站首页 | 关于我们 | 联系我们 | 产品服务 | 客服中心 | 广告服务 | 版权声明 | 网站联盟 | 友情链接 | 售卡网点

版权所有© 渝B2-20050021-1 渝公网安备 50019002500403号 违法和不良信息举报中心

互联网出版许可证 新出网证(渝)字10号 全国400电话 - 免长途话费