High-Throughput Powder Diffraction Using White X-Ray Beam and a Simulated Energy-Dispersive Array Detector

查看全文 作  者:Xiaoping [1]Wang;Weiwei [2]Dong;Peng [3]Zhang;Haoqi [5]Tang;Lanting [1]Zhang;Tieying [5]Yang;Peng [2]Liu;Hong [1]Wang;X.-[3,4,6,7]D.Xiang 高影响力作者 机构地区:[1]Materials Genome Initiative Center&School of Materials Science and Engineering,Shanghai Jiao Tong University,Shanghai 200240,China;[2]Institute of High Energy Physics,Chinese Academy of Sciences,Beijing 100049,China;[3]Academy for Advanced Interdisciplinary Studies,Southern University of Science and Technology,Shenzhen 518055,China;[4]Department of Materials Science and Engineering&Department of Physics,Southern University of Science and Technology,Shenzhen 518055,China;[5]Shanghai Advanced Research Institute,Chinese Academy of Sciences,Shanghai 201204,China;[6]Guangdong Provincial Key Laboratory of Energy Materials for Electric Power,Southern University of Science and Technology,Shenzhen 518055,China;[7]Guangdong-Hong Kong-Macao Joint Laboratory for Photonic-Thermal-Electrical Energy Materials and Devices,Southern University of Science and Technology,Shenzhen 518055,China高影响力机构 出  处:《Engineering》索引2022年第8卷第3期,共8页高影响力期刊 基  金:supported by the National Key Research and Development Program of China,China(2017YFB0701900);High-Level Special Funds(G02256401 and G02256301);supported by the fund of the Guangdong Provincial Key Laboratory(2018B030322001);the Guangdong-Hong Kong-Macao Joint Laboratory(2019B121205001)。 摘  要:High-throughput powder X-ray diffraction(XRD)with white X-ray beam and an energy-dispersive detector array is demonstrated in this work on a CeO;powder sample on a bending magnet synchrotron beamline at the Shanghai Synchrotron Radiation Facility(SSRF),using a simulated energy-dispersive array detector consisting of a spatially scanning silicon-drift detector(SDD).Careful analysis and corrections are applied to account for various experimental hardware-related and diffraction angle-related factors.The resulting diffraction patterns show that the relative strength between different diffraction peaks from energy-dispersive XRD(EDXRD)spectra is consistent with that from angle-resolved XRD(ARXRD),which is necessary for analyzing crystal structures for unknown samples.The X-ray fluorescence(XRF)signal is collected simultaneously.XRF counts from all pixels are integrated directly by energy,while the diffraction spectra are integrated by d-spacing,resulting in a much improved peak strength and signal-to-noise(S/N)ratio for the array detector.In comparison with ARXRD,the diffraction signal generated by a white X-ray beam over monochromic light under the experimental conditions is about 104 times higher.The full width at half maximum(FWHM)of the peaks in q-space is found to be dependent on the energy resolution of the detector,the angle span of the detector,and the diffraction angle.It is possible for EDXRD to achieve the same or even smaller FWHM as ARXRD under the energy resolution of the current detector if the experimental parameters are properly chosen. 关 键 词:High-throughput experiment White beam X-ray diffraction Energy-dispersive array detector Energy-dispersive X-ray diffraction Angle-resolved X-ray diffraction
相关文献

参考文献(24)

耦合文献(6)

网站首页 | 关于我们 | 联系我们 | 产品服务 | 客服中心 | 广告服务 | 版权声明 | 网站联盟 | 友情链接 | 售卡网点

版权所有© 渝B2-20050021-1 渝公网安备 50019002500403号 违法和不良信息举报中心

互联网出版许可证 新出网证(渝)字10号 全国400电话 - 免长途话费