维普中文期刊产品整合服务

A pediatric robotic thumb exoskeleton for at-home rehabilitation The isolated orthosis for thumb actuation(IOTA)

查看全文 作  者:Patrick [1]Aubin;Kelsey [2]Petersen;Hani [1]Sallum;Conor [1]Walsh;Annette [3]Correia;Leia [4]Stirling 高影响力作者 机构地区:[1]Rehabilitation and Development Center of Excellence for Limb Loss Prevention and Prosthetic Engineering,VA Puget Sound Health Care System,Seattle,Washington,USA;[2]Wyss Institute for Biologically Inspired Engineering,Harvard University,Boston,Massachusetts,USA;[3]Boston Children’s Hospital,Boston,Massachusetts,USA;[4]Wyss Institute for Biologically Inspired Engineering,Harvard University,Boston,Massachusetts,USA and Massachusetts Institute of Technology,Cambridge,Massachusetts,USA高影响力机构 出  处:《International Journal of Intelligent Computing and Cybernetics》索引2014年第7卷第3期,共20页高影响力期刊 摘  要:Purpose–Pediatric disorders,such as cerebral palsy and stroke,can result in thumb-in-palm deformity greatly limiting hand function.This not only limits children’s ability to perform activities of daily living but also limits important motor skill development.Specifically,the isolated orthosis for thumb actuation(IOTA)is 2 degrees of freedom(DOF)thumb exoskeleton that can actuate the carpometacarpal(CMC)and metacarpophalangeal(MCP)joints through ranges of motion required for activities of daily living.The paper aims to discuss these issues.Design/methodology/approach–IOTA consists of a lightweight hand-mounted mechanism that can be secured and aligned to individual wearers.The mechanism is actuated via flexible cables that connect to a portable control box.Embedded encoders and bend sensors monitor the 2 DOF of the thumb and flexion/extension of the wrist.A linear force characterization was performed to test the mechanical efficiency of the cable-drive transmission and the output torque at the exoskeletal CMC and MCP joints was measured.Findings–Using this platform,a number of control modes can be implemented that will enable the device to be controlled by a patient to assist with opposition grasp and fine motor control.Linear force and torque studies showed a maximum efficiency of 44 percent,resulting in a torque of 2.3971.06 in.-lbf and 0.6970.31 in.-lbf at the CMC and MCP joints,respectively.Practical implications–The authors envision this at-home device augmenting the current in-clinic and at-home therapy,enabling telerehabilitation protocols.Originality/value–This paper presents the design and characterization of a novel device specifically designed for pediatric grasp telerehabilitation to facilitate improved functionality and somatosensory learning。 关 键 词:PEDIATRIC EXOSKELETON At-home hand rehabilitation Rehabilitation robotics THUMB
相关文献

参考文献(29)

引证文献(2)

网站首页 | 关于我们 | 联系我们 | 产品服务 | 客服中心 | 广告服务 | 版权声明 | 网站联盟 | 友情链接 | 售卡网点

版权所有© 渝B2-20050021-1 渝公网安备 50019002500403号 违法和不良信息举报中心

互联网出版许可证 新出网证(渝)字10号 全国400电话 - 免长途话费