A preliminary experimental investigation on the biotribocorrosion of a metal-on-polyethylene hip prosthesis in a hip simulator

查看全文 作  者:Shu [1,2]YANG;Jian [1]PU;Xiaogang [1]ZHANG;Yali [1]ZHANG;Wen [1]CUI;Fengbao [2]XIE;Weiping [2]LU;Qin [1]TAN;Zhongmin [1,3]JIN 高影响力作者 机构地区:[1]Tribology Research Institute,School of Mechanical Engineering,Southwest Jiaotong University,Chengdu,610031,China;[2]Beijing Chunlizhengda Medical Instruments Co.,Ltd.,Beijing,101100,China;[3]School of Mechanical Engineering,University of Leeds,Leeds,LS29JT,UK高影响力机构 出  处:《Friction》索引2023年第11卷第6期,共13页高影响力期刊 基  金:supported by the National Natural Science Foundation of China(52035012);the Science and Technology Planning Project of Sichuan Province(2020YJ0032);the 111 Project(B20008). 摘  要:Corrosion at the taper/trunnion interface of total hip replacement(THR)often results in severe complications.However,the underlying mechanisms of biotribocorrosion at the taper/trunnion interface during the long-term walking gait cycles remain to be fully understood.In this study,a hip joint simulator was therefore instrumented with an electrochemical cell for in-situ monitoring of the tribocorrosion evolution in a metal-on-polyethylene(MoP)THR during a typical long-term walking gait.In addition,the biotribocorrosion mechanism was investigated via surface and chemical characterizations.The experimental results confirmed that the taper/trunnion interface dominated the contemporary MoP hip joint corrosion.Three cyclic variations in the open circuit potential(OCP)were observed throughout the long-term electrochemical measurements,attributed to the formation and disruption of the adsorbed protein layer.The corrosion exhibited an initial increase at each period,peaking at approximately 0.125 million cycles,followed by a subsequent gradual reduction.Surface and chemical analyses revealed the formation of a tribochemical reaction layer(tribolayer)on the worn surface of the taper/trunnion interface.The surface/chemical characterizations and the electrochemical measurements indicated that the adhesion force of the adsorbed protein layer was weaker than that of the tribolayer.In contrast,the opposite was true for the corrosion resistance.Based on the observations from this study,the tribocorrosion mechanism of the taper/trunnion interface under the long-term walking gait cycles is deduced. 关 键 词:biotribocorrosion metal-on-polyethylene(MoP) adsorbed protein layer total hip replacement(THR)
相关文献

参考文献(33)

引证文献(2)

网站首页 | 关于我们 | 联系我们 | 产品服务 | 客服中心 | 广告服务 | 版权声明 | 网站联盟 | 友情链接 | 售卡网点

版权所有© 渝B2-20050021-1 渝公网安备 50019002500403号 违法和不良信息举报中心

互联网出版许可证 新出网证(渝)字10号 全国400电话 - 免长途话费