维普中文期刊产品整合服务
3篇 您的检索式:作者名="DENG Jiangang"
    题名 作者 年代 出处 被引量
1Surface Partial Discharge Characteristics of Oil-paper Insulation Under Combined AC-DC Voltage显示文摘The valve side windings of converter transformers bear AC, DC, impulse, and reversal-polarity voltages during operation, which could result in serious insulation problems of the equipment. By performing experiments with surface discharge model of oil-paper insula- tion at 80 ℃ under combined AC-DC voltage for 200 h, we studied the spectrums and statistical parameters of partial discharges at different discharge stages. Furthermore, some fingerprint parameters were calculated in order to estimate the development situation of par- tial discharge, while the characteristic gases dissolved in the transformer oil were measured by gas chromatography. The surface discharges in the experiments were observed using a high speed camera, and a full discharge process could be marked off into four stages as follows. ①The elementary stage. When a partial discharge occurs near electrodes, electrical charges are injected into the region near electrodes and causing bubble generation. ②Due to their high resistivity and low dielectric constant, the bubbles would bare the major part of the voltage applied to samples. Therefore, discharge happens inside the small bubbles, and it emits a lot of light. ③Micromolecules of gas are produced in discharge, and further ionization in the transformer oil takes place simultaneously when high-energy electrons collide with oil molecules. ④The carrier charge moves forward to electrodes driven by the applied electric field, till they neutralize with the charge from electrodes, and hence discharge channels are formed subsequently.SHA Yanchao ZHOU Yuanxiang NIE Dexin WU Zhirong DENG Jiangang LU Licheng 2013高电压技术2013,39,8:5
2Development and Application of DC Partial Discharge Test System显示文摘Direct current (DC) partial discharge (PD) test has drawn extensive attention from world-wide electric power research institutes in recent years. However, presently, no DC PD detection device on the market has the statistical function. Thus, we developed a test system for PD detection under DC voltage, which is characterized by strong anti-jamming capability, continuous high-speed real-time data acquisi- tion and effective, complete detection of DC PD signals. The DC PD mechanism, as well as the measuring principles, software system, and hardware design of the test equipment were introduced. Adopting typical electrode pairs, we tested the statistical spectrum of PD under DC voltage. The main difference in statistical spectrums between parallel plate electrodes and needle-plate electrodes was that the time interval between two consecutive discharges for needle-plate electrodes has obviously larger variation range than that for parallel plate electrodes, which could be the convincing proof for distinguishing the type of electrodes under DC PD. Practical results indicate that the proposed sys- tem can measure time domain signals of DC PD of oil-paper insulation effectively and promptly, and it can be used to determine and detect defects in DC power transmission equipment.NIE Dexin SHA Yanchao ZHOU Yuanxiang WU Zhirong DENG Jiangang 2013高电压技术2013,39,8:2
3Characteristics of Polysaccharides Variation in Sludge in Sludge Drying Reed Beds显示文摘Rui Chen Yubo Cui Wei Gao Xinnan Deng Jiangang Li 2015环境科学前沿(中英文版)2015,4,1:0
返回顶部 每页显示:
共1页 首页 上一页 第1页 下一页 末页 /1 跳转

网站首页 | 关于我们 | 联系我们 | 产品服务 | 客服中心 | 广告服务 | 版权声明 | 网站联盟 | 友情链接 | 售卡网点

版权所有© 渝B2-20050021-1 渝公网安备 50019002500403号 违法和不良信息举报中心

互联网出版许可证 新出网证(渝)字10号 全国400电话 - 免长途话费