维普中文期刊产品整合服务
2篇 您的检索式:作者名="Hanting Peng"
    题名 作者 年代 出处 被引量
1Mahalanobis-Taguchi system: a systematic review from theory to application显示文摘The Mahalanobis-Taguchi system(MTS)is a relatively new multi-dimensional pattern recogni-tion technology that combines Mahalanobis distance(MD)with Taguchi’s robust engineering for diagnosis and prognosis.MTS operation process generally consists of four specialised stages,namely,Mahalanobis space(MS)construction,MS validation,MS optimisation,and diagnosis and prognosis.In recent years,a significant amount of research work has been conducted on the improvement of key technologies and these four processes.Numerous applications of MTS have also been studied in various fields.There are,of course,excellent reviews of theoretical research and applied research of MTS.However,there is no systematic review that covers both theoretical and applied research comprehensively.To fill this gap,this paper reviews MTS from key technolo-gies,four processes and application research,and provides researchers with a discussion of the current situation,upcoming challenges and possible future trends.Zhaiming Peng Longsheng Cheng Qifeng Yao Hanting Zhou 2022Journal of Control and Decision2022,9,2:0
2Calculation Method for Commutation Failure Fault Level in LCC-HVDC System Under Single-line-to-ground Faults Considering DC Current Variation显示文摘Earlier studies have reported some calculation methods for commutation failure fault level(CFFL) in line-commutated-converter based high-voltage direct current(LCCHVDC) system under single-line-to-ground(SLG) faults. The accuracy of earlier methods is limited because they only consider the commutating voltage drop and phase shift, while neglecting the DC current variation. Hence, this paper proposes a CFFL calculation method under SLG faults considering DC current variation, for better planning and designing of LCC-HVDC systems. First, the fault commutating voltage magnitude and phase shift are calculated. Then, the fault DC voltage during different commutation processes is deduced. Based on the commutating voltage magnitude and phase shift, and DC voltage during different commutation processes under SLG faults, the characteristics of CFFL with different fault time are demonstrated and analyzed. Next, the transient time-domain response of the DC current after the fault is obtained based on the DC transmission line model. Discrete commutation processes are constructed based on the commutation voltage-time area rule to solve the extinction angle under different fault levels and fault time. Finally, the CFFL is calculated considering the fault time, commutating voltage drop, phase shift, and DC current variation. The accuracy of the proposed method compared with the traditional method is validated based on the CIGRE benchmark model in PSCAD/EMTDC.Renlong Zhu Xiaoping Zhou Hanhang Yin Lerong Hong An Luo Yandong Chen Hanting Peng 2023Journal of Modern Power Systems and Clean Energy2023,11,6:0
返回顶部 每页显示:
共1页 首页 上一页 第1页 下一页 末页 /1 跳转

网站首页 | 关于我们 | 联系我们 | 产品服务 | 客服中心 | 广告服务 | 版权声明 | 网站联盟 | 友情链接 | 售卡网点

版权所有© 渝B2-20050021-1 渝公网安备 50019002500403号 违法和不良信息举报中心

互联网出版许可证 新出网证(渝)字10号 全国400电话 - 免长途话费