维普中文期刊产品整合服务
2篇 您的检索式:作者名="Liu Wengu"
    题名 作者 年代 出处 被引量
1Approach to Nonrigid Body Metamorphosis Using Generalized Morph-translation显示文摘An approach of morphing by decomposing two objects into sets of individual convex sub objects respectively and contructing the mapping between two sets is presented The Minkvski addition of two convex sub-objects according to their mapping ralationship is calculated, then all the Minkovski additions are combined to obtain the final result. Nonrigid body motion can be divided into nonrigid body metamorphosis and rigid body rotation A novel method for describing nonrigid body motion based on generalized morph-translation is proposed. This method can solve the metamorphosis problem of two non-homotopic objects. Experiments show tha this method can generate natural, high quality metamorphosis results with simple computation. This method can also be used in interpolation between two keyframes in 2D and 3D computer animation automatically.Liu Wengu Li Hua Thu Guangxi (Department of Electronics & Information Engineering Huazhong University of Science & Technology Wuhan, Hubei 430074, P R. China ) 2000Computer Aided Drafting,Design and Manufacturing2000,10,1:0
2Coordinated Rotor-Side Control Strategy for Doubly-FedWind Turbine under Symmetrical and Asymmetrical Grid Faults显示文摘In order to solve the problems of rotor overvoltage,overcurrent and DC side voltage rise caused by grid voltage drops,a coordinated control strategy based on symmetrical and asymmetrical low voltage ride through of rotor side converter of the doubly-fed generator is proposed.When the power grid voltage drops symmetrically,the generator approximate equation under steady-state conditions is no longer applicable.Considering the dynamic process of stator current excitation,according to the change of stator flux and the depth of voltage drop,the system can dynamically provide reactive power support for parallel nodes and suppress the rise of DC side voltage and rotor over-current.When the grid voltage drops asymmetrically,the positive and negative sequence components are separated in the rotating coordinate system.The doubly fed generator model is established to suppress the rotor positive sequence current and negative sequence current respectively.At the same time,the output voltage limit of the converter is discussed,and the reference value is adjusted within the allowable output voltage range.In order to adapt to the occurrence of different types of power grid faults and complex operating conditions,a fast switching module of fault type detection and rotor control mode is designed to detect the type of power grid faults and voltage drop depth in real time and switch the rotor side control mode dynamically.Finally,the simulation model of the doubly fed wind turbine is constructed in Matlab/Simulink.The simulation results verify that the proposed control strategy can improve the low-voltage ride through performance of the system when dealing with the symmetrical and asymmetric voltage drop of the power grid and identify the power grid fault type and provide the correct control strategy.Quanchun Yan Chao Yuan WenGu Yanan Liu Yiming Tang 2023Energy Engineering2023,120,1:0
返回顶部 每页显示:
共1页 首页 上一页 第1页 下一页 末页 /1 跳转

网站首页 | 关于我们 | 联系我们 | 产品服务 | 客服中心 | 广告服务 | 版权声明 | 网站联盟 | 友情链接 | 售卡网点

版权所有© 渝B2-20050021-1 渝公网安备 50019002500403号 违法和不良信息举报中心

互联网出版许可证 新出网证(渝)字10号 全国400电话 - 免长途话费