维普中文期刊产品整合服务
5篇 您的检索式:作者名="Pavol Bauer"
    题名 作者 年代 出处 被引量
1Coordination Control of Power Flow Controller and Hybrid DC Circuit Breaker in MVDC Distribution Networks显示文摘The two main challenges of medium voltage direct current(MVDC)distribution network are the flexible control of power flow(PF)and fault protection.In this paper,the power flow controller(PFC)is introduced to regulate the PF and inhibit the fault current during the DC fault.The coordination strategy of series-parallel PFC(SP-PFC)and hybrid DC circuit breaker(DCCB)is proposed.By regulating the polarity and magnitude of SP-PFC output voltage during the fault,the rising speed of fault current can be suppressed so as to reduce the breaking current of hybrid DCCB.The access mode of SP-PFC to the MVDC distribution network and its topology are analyzed,and the coordination strategy between SP-PFC and hybrid DCCB is investigated.Moreover,the emergency control and bypass control strategies of SP-PFC are developed.On this basis,the mathematical model of SP-PFC in different fault stages is derived.With the equivalent model of SP-PFC,the fault current of the MVDC distribution network can be calculated accurately.A simulation model of the MVDC distribution network containing SP-PFC is established in MATLAB/Simulink.The fault current calculation result is compared with the simulation result,and the effectiveness of the proposed coordination strategy is verified.Jianquan Liao Niancheng Zhou Zian Qin Pavel Purgat Qianggang Wang Pavol Bauer 2021Journal of Modern Power Systems and Clean Energy2021,9,6:4
2Control method for wireless inductive energy transfer systems with relatively large air gap显示文摘Frank van der Pijl Pavol Bauer 2013IEEE Transactions on industrial electronics2013,60,1:1
3Practical capacity fading model for Li-Ion battery cells in electric vehicles显示文摘Long Lam Bauer Pavol 2013IEEE Transactions on Power Electronics2013,28,12:1
4Python Supervised Co-simulation for a Day-long Harmonic Evaluation of EV Charging显示文摘To accurately simulate electric vehicle DC fast chargers'(DCFCs')harmonic emission,a small time step,i.e.,typically smaller than 10μs,is required owing to switching dynamics.However,in practice,harmonics should be continuously assessed with a long duration,e.g.,a day.A trade-off between accuracy and time efficiency thus exists.To address this issue,a multi-time scale modeling framework of fast-charging stations(FCSs)is proposed.In the presented framework,the DCFCs'input impedance and harmonic current emission in the ideal grid condition,that is,zero grid impedance and no background harmonic voltage,are obtained based on a converter switching model with a small timescale simulation.Since a DCFC's input impedance and harmonic current source are functions of the DCFC's load,the input impedance and harmonic emission at different loads are obtained.Thereafter,they are used in the fast-charging charging station modeling,where the DCFCs are simplified as Norton equivalent circuits.In the station level simulation,a large time step,i.e.,one minute,is used because the DCFCs'operating power can be assumed as a constant over a minute.With this co-simulation,the FCSs'long-term power quality performance can be assessed time-efficiently,without losing much accuracy.Lu Wang Zian Qin Lucia Beloqui Larumbe Pavol Bauer 2021Chinese Journal of Electrical Engineering2021,7,4:0
5Power Electronics of Hybrid Power Source显示文摘Jan Leuchter Pavol Bauer 2012通讯和计算机(中英文版)2012,9,10:0
返回顶部 每页显示:
共1页 首页 上一页 第1页 下一页 末页 /1 跳转

网站首页 | 关于我们 | 联系我们 | 产品服务 | 客服中心 | 广告服务 | 版权声明 | 网站联盟 | 友情链接 | 售卡网点

版权所有© 渝B2-20050021-1 渝公网安备 50019002500403号 违法和不良信息举报中心

互联网出版许可证 新出网证(渝)字10号 全国400电话 - 免长途话费