维普中文期刊产品整合服务
1篇 您的检索式:作者名="Said M.Ali"
    题名 作者 年代 出处 被引量
1Performance of a real-time PCR approach for diagnosing Schistosoma haematobium infections of different intensity in urine samples from Zanzibar显示文摘Background:Efforts to control and eliminate schistosomiasis have accelerated over the past decade.As parasite burden,associated morbidity and egg excretion decrease,diagnosis with standard parasitological methods becomes harder.We assessed the robustness and performance of a real-time PCR(qPCR)approach in comparison with urine filtration microscopy and reagent strip testing for the diagnosis of Schistosoma haematobium infections of different intensities.Methods:The robustness of DNA isolation and qPCR was validated in eight laboratories from Europe and Africa.Subsequently,792 urine samples collected during cross-sectional surveys of the Zanzibar Elimination of Schistosomiasis Transmission(ZEST)project in 2012-2017 were examined with qPCR in 2018.Diagnostic sensitivity of the qPCR was calculated at different infection intensity categories,using urine filtration microscopy as reference test.Spearman's rank correlation between Ct-values and S.haematobium egg counts was assessed and Ct-value percentiles for infection intensity categories determined.Results:S.haematobium Dra1 DNA-positive samples were identified correctly in all eight laboratories.Examination of urine samples from Zanzibar revealed Dra1 DNA in 26.8%(212/792)by qPCR,S.haematobium eggs in 13.3%(105/792)by urine filtration,and microhaematuria in 13.8%(109/792)by reagent strips.Sensitivity of the qPCR increased with augmenting egg counts:80.6%(29/36)for counts between 1 and 4 eggs,83.3%(15/18)for counts between 5 and 9 eggs,100%(23/23)for counts between 10 and 49 eggs,and 96.4%(27/28)for counts of 50+eggs.There was a significant negative correlation between Ct-values and egg counts(Spearman's rho=-0.49,P<0.001).Seventy-five percent of the Ct-values were≥33 in the egg-negative category,<31 in the light intensity category,and<24 in the heavy intensity category.Conclusions:While the sensitiivity of the qPCR was^80%for very light intensity infections(egg counts<10),in general,the Dra1 based qPCR assay detected twice as many S.haematobium infections compared with classical parasitological tests.The qPCR is hence a sensitive,urine-based approach for S.haernatcbium diagnosis that can be used for impact assessment of schistosomiasis elimination programmes,individual diagnosis,and in improved format also for verification and certification of elimination.Trial registration:ISRCTN,ISRCTN48837681.Registered 05 September 2012-Retrospectively registered.Dominique Keller Julian Rothen Jean-Pierre Dangy Corina Saner Claudia Daubenberger Fiona Allan Shaali M.Ame Said M.Ali Fatma Kabole Jan Hattendorf David Rollinson Ralf Seyfarth Stefanie Knopp 2020Infectious Diseases of Poverty2020,9,5:0
返回顶部 每页显示:
共1页 首页 上一页 第1页 下一页 末页 /1 跳转

网站首页 | 关于我们 | 联系我们 | 产品服务 | 客服中心 | 广告服务 | 版权声明 | 网站联盟 | 友情链接 | 售卡网点

版权所有© 渝B2-20050021-1 渝公网安备 50019002500403号 违法和不良信息举报中心

互联网出版许可证 新出网证(渝)字10号 全国400电话 - 免长途话费