维普中文期刊产品整合服务
2篇 您的检索式:作者名="Xingtang Zhao"
    题名 作者 年代 出处 被引量
1Molecular cloning and expression under abiotic stresses and hormones of the ethylene response factor Ⅶ gene FmRAP2.12 from Fraxinus mandshurica显示文摘RELATED TO AP2.12(RAP2.12)is one of the Ethylene Response Factors(ERF)transcription factor and plays a key role in controlling plant root bending and responding to multiple abiotic stresses including hypoxia stress.In this study,FmRAP2.12 gene was isolated and characterized from Fraxinus mandshurica Rupr.The open reading frame(ORF)of FmRAP2.12 was 1170 bp and encoded a protein of 389 amino acids.The conserved domains,three-dimensional phylogenetic relationship of FmRAP2.12 was also investigated.Quantitative real-time(qRT-PCR)analyzed the expression of FmRAP2.12 in different tissues.The expression level of FmRAP2.12 was highest in roots followed by leaves,and lowest in male flowers.Abiotic stress and hormone signal-induced expression was established using qRT-PCR.Salt stress induced FmRAP2.12 to a double peak pattern:the first peak value was at 6 h and the second at 72 h.Drought stress also induced FmRAP2.12 to a double peak pattern:the first at6 h and the second at 48 h.FmRAP2.12 was up-regulated after initiation of gibberellic acid(GA3)treatment,with a one peak pattern at 24 h.FmRAP2.12 may not respond to cold stress and Abscisic acid(ABA)treatment.The transient overexpression of FmRAP2.12 caused the up-expression of downstream key genes of abiotic stress response and gibberellin pathway.Our research reveals the molecular characteristic and expression patterns under abiotic stress and hormone condition of FmRAP2.12,providing support for the genetic improvement of F.mandshurica at a molecular level.Nansong Liang Lei Yu Chunhao Liu Ziqing Wang Xingtang Zhao Yaguang Zhan 2019Journal of Forestry Research2019,30,4:3
2Robust Load Frequency Control for Isolated Microgrids Based on Double-loop Compensation显示文摘Frequency is an important indicator for the oper-ation of microgrids.However,the randomness and uncertainty of renewable energy and load variability may lead to frequency undulation.So,a robust load frequency control(LFC)is pro-posed for isolated wind-diesel microgrids considering time delay and parameter uncertainty.The control strategy can suppress frequency fuctuation and optimize frequency dynamic response.First,the double compensation loop,including feedforward control and integral sliding mode control(SMC),is devised to provide anti-disturbance compensation for the diesel generator system and ameliorate the frequency stability of independent microgrids.Secondly,a dynamic fuzzy controller,composed of wind speed and load demand,is designed to provide real-time response reference power for doubly fed induction generator systems(DFIGs),which can promote the effective participation of a wind turbine system for frequency regulation.Then,the proportional differential(PD)parameters of a dynamic fuzzy controller and the frequency adjustment compensation of DFIGs can be obtained by using a particle swarm optimization(PSO)algorithm.Thirdly,load demand is an important index of the robust dynamic load frequency control method;the radial basis function(RBF)neural network observer(NNO)based on the LFC model is presented to obtain more accurate load deviations and improve the control precision of LFC.The performance of the proposed LFC method is tested under different operation cases.Index Terms-Load frequency control,microgrid,neural network observer,sliding mode,time delay and parameter uncertainty.Yang Mi Yuchen Ma Xingtang He Xingwu Yang Jinxia Gong Yao Zhao Ronghui Liu Wei Wei 2023CSEE Journal of Power and Energy Systems2023,9,4:0
返回顶部 每页显示:
共1页 首页 上一页 第1页 下一页 末页 /1 跳转

网站首页 | 关于我们 | 联系我们 | 产品服务 | 客服中心 | 广告服务 | 版权声明 | 网站联盟 | 友情链接 | 售卡网点

版权所有© 渝B2-20050021-1 渝公网安备 50019002500403号 违法和不良信息举报中心

互联网出版许可证 新出网证(渝)字10号 全国400电话 - 免长途话费