维普中文期刊产品整合服务
2篇 您的检索式:作者名="Zihan Teng"
    题名 作者 年代 出处 被引量
1Analysis of Conducted Disturbance via Current Transformer Due to Switch Operation of GIS Disconnector in UHV Substation显示文摘The characteristics of conducted disturbances via current transformer(CT)caused by switch operations in 1000 kV UHV substations are studied in this paper.Since the broadband circuit models might have limitations on the stability and accuracy for CT conducted disturbance simulation,a frequencydomain simulation method without circuit synthesis is proposed based on VFTC spectrum and CT transfer characteristics.To improve VFTC simulation accuracy,both the bushing radiation loss and frequency-dependent earth impedance are taken into consideration.Transfer characteristics of three types of windings for the 1000 kV GIS CT are ingeniously measured from a combination of fast and slow impulse tests.Through conducted disturbances simulations in UHV Wuhu substation,bushing radiation loss is found to have a suppression effect on the highfrequency response but the effect of frequency-dependent earth impedance can be ignored.As a result,the maximum amplitude of 84.5 A for the conducted disturbance is obtained,thus a fast damped oscillatory wave immunity test with no lower than Level 4 from IEC standard is suggested to test the anti-interference performance of the secondary equipment in UHV substation.Jun Zhao Weijiang Chen Kejie Li Zihan Teng Ni Li Tao Wen Xing Fan 2023CSEE Journal of Power and Energy Systems2023,9,3:0
2Dispersion characteristics of switching transients from large‐scale experiments in a 1100 kV gas insulated switchgear circuit显示文摘The switching operation of gas insulated switchgear(GIS)disconnector will produce multiple random spark discharges between the gas gaps of the disconnector.Each spark discharge can be affected by various random factors,such as trapped charge on the load side,the initial operating phase,gap distance and operating speed of the disconnector,leading to dispersion characteristics.At present,some studies have mentioned this dispersion,but its impact is still unclear due to the lack of experimental data,resulting in a deviation between the simulation results and the measured results.In this study,thousands of switching operations were carried out based on the 1100 kV full‐scale GIS circuit in Wuhan ultra‐high voltage alternating current Test Base.The maximal information coeffi-cient analysis,linear regression fitting and other statistical methods were used to discuss the dispersion characteristics of very fast transient overvoltage(VFTO)and transient enclosure voltage(TEV)from large‐scale experimental data.The results show that the dispersion of VFTO and TEV in amplitude aspects both increase gradually as the breakdown voltage increases,with the maximum difference of five times of TEV amplitude at normalised breakdown voltage.In terms of frequency characteristics,the dispersion of different fre-quency components in TEV is always greater than that of VFTO,especially for the high‐frequency components.Moreover,by comparing the frequency characteristics of TEV at different positions,we notice that the dispersion is almost independent of the spatial po-sition but only determined by the randomness of spark discharges.These discoveries reveal the importance of the dispersion in switching transients and make up for the lack of theoretical understanding of the correlation among them.Zihan Teng Weijiang Chen Jiangong Zhang Baoquan Wan Jun Zhao Kejie Li Zhenghai Liao Zheyuan Gan 2023High Voltage2023,8,6:0
返回顶部 每页显示:
共1页 首页 上一页 第1页 下一页 末页 /1 跳转

网站首页 | 关于我们 | 联系我们 | 产品服务 | 客服中心 | 广告服务 | 版权声明 | 网站联盟 | 友情链接 | 售卡网点

版权所有© 渝B2-20050021-1 渝公网安备 50019002500403号 违法和不良信息举报中心

互联网出版许可证 新出网证(渝)字10号 全国400电话 - 免长途话费