维普中文期刊产品整合服务

The Analysis of Wall Shear Stress Modulated by Acute Exercise in the Human Common Carotid Artery with an Elastic Tube Model

查看全文 作  者:Yanxia [1]Wang;Yu [2]Wang;Siqi [3]Li;Aziz ur Rehman [3]Aziz;Shutian [1]Liu;Kairong [2]Qin 高影响力作者 机构地区:[1]Department of Engineering Mechanics,State Key Laboratory of Structural Analysis for Industrial Equipment,Dalian University of Technology,No.2,Linggong Road,Dalian,116024,China.;[2]School of Optoelectronic Engineering and Instrumentation Science,Dalian University of Technology,No.2,Linggong Road,Dalian,116024,China.;[3]School of Biomedical Engineering,Dalian University of Technology,No.2,Linggong Road,Dalian,116024,China.高影响力机构 出  处:《Computer Modeling in Engineering & Sciences》索引2018年第8期,共21页高影响力期刊 基  金:The research described in this paper was supported in part by the National Natural Science Foundation of China(Grant No.31370948,11672065). 摘  要:Assessment of the magnitude and pattern of wall shear stress(WSS)in vivo is the prerequisite for studying the quantitative relationship between exercise-induced WSS and arterial endothelial function.In the previous studies,the calculation of the WSS modulated by exercise training was primarily based upon the rigid tube model,which did not take non-linear effects of vessel elastic deformation into consideration.In this study,with an elastic tube model,we estimated the effect of a bout of 30-minute acute cycling exercise on the WSS and the flow rate in the common carotid artery according to the measured inner diameter,center-line blood flow velocity,heart rates and the brachial blood pressures before and after exercise training.Furthermore,the roles of exerciseinduced arterial diameter and blood flow rate in the change of WSS were also determined.The numerical results demonstrate that acute exercise significantly increases the magnitudes of blood flow rate and WSS.Moreover,the vessel elastic deformation is a non-negligible factor in the calculation of the WSS induced by exercise,which generates greater effects on the minimum WSS than the maximum WSS.Additionally,the contributions of exercise-induced variations in blood flow rate and diameter are almost identical in the change of the mean WSS. 关 键 词:Acute CYCLING exercise blood flow wall shear stress common CAROTID ARTERY ELASTIC TUBE MODEL rigid TUBE MODEL
相关文献

参考文献(37)

引证文献(2)

网站首页 | 关于我们 | 联系我们 | 产品服务 | 客服中心 | 广告服务 | 版权声明 | 网站联盟 | 友情链接 | 售卡网点

版权所有© 渝B2-20050021-1 渝公网安备 50019002500403号 违法和不良信息举报中心

互联网出版许可证 新出网证(渝)字10号 全国400电话 - 免长途话费