维普中文期刊产品整合服务
5篇 您的检索式:作者名="Beihua CONG"
    题名 作者 年代 出处 被引量
1Mechanisms of suppressing cup-burner flame with water vapor显示文摘The mechanisms of suppressing a laminar methane-air co-flow diffusion flame formed on a cup burner with water vapor have been studied experimentally and numerically. The methane burned in a steel cup surrounded by a glass chimney. A mist generator produced fine droplets delivered though the glass chimney with air. These droplets were heated into water vapor when they went though the diffuser. The extinguishing limit was obtained by gradually increasing the amount of water vapor to replace the air in the coflowing oxidizer stream. Results showed that the agent concentration required for extinguishment was constant over a wide range of the oxidizer velocity, i.e., a so-called 'plateau region'. The measured extinguishing mass fractions of the agents were: (16.7 ± 0.6)% for H2O, (15.9 ± 0.6)% for CO2, and (31.9 ± 0.6)% for N2. The computation used the Fire Dynamics Simulator (FDS) de- veloped by the NIST. The numerical simulations showed that the predicted water vapor extinguishing limits and the flickering frequency were in good agreements with the experimental observations and, more importantly, revealed that the sup- pression of cup-burner flames occurred via a partial extinction mechanism (in which the flame base drifts downstream and then blows off) rather than the global extinction mechanism of typical counter-flow diffusion flames. And the flame-base oscillation just before the blow-off was the key step for the non-premixed flame extinction in the cup burner.CONG BeiHua LIAO GuangXuan 2008Science China(Technological Sciences)2008,51,8:5
2Experimental studies on interaction of water mist with class K fires显示文摘Interaction of water mist with cooking oil fires is studied experimentally and theoretically. A LDV/APV system is used to measure the velocity and diameter of water mist at different pressures in the experiments,and the effect of water mist velocity and diameter on fire extinguishment efficiency is investi-gated. The experimental results show that water mist has excellent surface cooling effect; it can control and extinguish cooking oil fires quickly without re-ignition. The critical temperature (Tfo) is calculated by energy balance equation,and the fire plume momentum is calculated and compared with that of water mist in order to determine the critical velocity (νwy) of fire extinguishment. This paper provides references for cooking oil fires extinguishment with water mist.FANG Yudong ZHANG Yongfeng LIN Lin LIAO Guangxuan HUANG Xin CONG Beihua 2006Chinese Science Bulletin2006,51,24:4
3Experimental Evaluation of Water Mist with Metal Chloride Additives for Suppressing CH_4 /Air Cup-Burner Flames显示文摘In order to investigate the fire suppression effectiveness of water mist with metal chloride additives, ultrafine water mists of these salts with diameters about 10μm were introduced into CH4 /air non-premixed flame in the cup burner. Results showed that these droplets hard to make itself to the flame front under the cup burner flow conditions functioned as a carrier of the vaporized solid particles or its decomposed materials. The metal chloride improved fire suppression efficacy of water mist which were affected by the type and concentration of metal chloride. On a mass basis, there is a fire suppression effectiveness relationship of MgCl2 Jianghong Liu Beihua Cong 2013Journal of Thermal Science2013,22,3:3
4Experimental study on inhibition of low pressure premixed flat methane-oxygen flames by trifluoromethane显示文摘This paper presents measurements of combus- tion species of low pressure laminar premixed flat meth- ane-oxygen flames inhibited by trifluoromethane (CF3H) using synchrotron radiation-molecular beam mass spec- trometry (SR-MBMS). Fire suppression chemistry of CF3H is investigated by selective detection of combustion radicals and intermediates. Results show that SR-MBMS offers a powerful tool for studying fire suppression chemistry of ha- lon replacements, which may extensively detect combustion species in the inhibited flames, especially radicals and inter- mediates. The suppressant CF3H is completely consumed in the preheat zone of premixed flames and produces fluori- nated radicals such as CF3 and CF2. CF3 is the main radical participating in flame inhibition cycles in the reactive zone. Unlike HBr, HF produced by CF3H is very stable and will not act as a radical scavenger because the bond energy of H-F is much higher than that of H-Br, which is responsible for less effectiveness than conventional bromine-based sup- pressants.CONG Beihua QI Fei LIAO Guangxuan KUANG Kaiqiang ZHOU Xiaomeng 2005Chinese Science Bulletin2005,50,14:2
5Simulation of steel beam under ceiling jet based on a wind–fire–structure coupling model显示文摘For localized fires, it is necessary to consider the thermal and mechanical responses of building elements subject to uneven heating under the influence of wind. In this paper, the thermomechanical phenomena experienced by a ceiling jet and I-beam in a structural fire were simulated. Instead of applying the concept of adiabatic surface temperature (AST) to achieve fluid–structure coupling, this paper proposes a new computational fluid dynamics–finite element method numerical simulation that combines wind, fire, thermal, and structural analyses. First, to analyze the velocity and temperature distributions, the results of the numerical model and experiment were compared in windless conditions, showing good agreement. Vortices were found in the local area formed by the upper and lower flanges of the I-beam and the web, generating a local high-temperature zone and enhancing the heat transfer of convection. In an incoming-flow scenario, the flame was blown askew significantly;the wall temperature was bimodally distributed in the axial direction. The first temperature peak was mainly caused by radiative heat transfer, while the second resulted from convective heat transfer. In terms of mechanical response, the yield strength degradation in the highest-temperature region in windless conditions was found to be significant, thus explaining the stress distribution of steel beams in the fire field. The mechanical response of the overall elements considering the incoming flows was essentially elastic.Jinggang ZHOU Xuanyi ZHOU Beihua CONG Wei WANG Ming GU 2023Frontiers of Structural and Civil Engineering2023,17,1:0
返回顶部 每页显示:
共1页 首页 上一页 第1页 下一页 末页 /1 跳转

网站首页 | 关于我们 | 联系我们 | 产品服务 | 客服中心 | 广告服务 | 版权声明 | 网站联盟 | 友情链接 | 售卡网点

版权所有© 渝B2-20050021-1 渝公网安备 50019002500403号 违法和不良信息举报中心

互联网出版许可证 新出网证(渝)字10号 全国400电话 - 免长途话费