|
|
|
题名
|
作者
|
年代
|
出处
|
被引量
|
| 1 | Effect of an Artificial Caudal Fin on the Performance of a Biomimetic Fish Robot Propelled by Piezoelectric Actuators显示文摘This paper addresses the design of a biomimetic fish robot actuated by piezoceramic actuators and the effect of artificial caudal fins on the fish robot's performance. The limited bending displacement produced by a lightweight piezocomposite actuator was amplified and transformed into a large tail beat motion by means of a linkage system. Caudal fins that mimic the shape of a mackerel fin were fabricated for the purpose of examining the effect of caudal fin characteristics on thrust pro-duction at an operating frequency range. The thickness distribution of a real mackerel's fin was measured and used to design artificial caudal fins. The thrust performance of the biomimetic fish robot propelled by fins of various thicknesses was examined in terms of the Strouhal number,the Froude number,the Reynolds number,and the power consumption. For the same fin area and aspect ratio,an artificial caudal fin with a distributed thickness shows the best forward speed and the least power con-sumption. | Seok Heo Tedy Wiguna Hoon Cheol Park Nam Seo Goo | 2007 | Journal of Bionic Engineering2007,4,3: | 16 |
| 2 | Stable Vertical Takeoff of an Insect-Mimicking Flapping-Wing System Without Guide Implementing Inherent Pitching Stability显示文摘 | Hoang Vu Phan Quoc Viet Nguyen Quang Tri Truong Tien Van Truong Hoon Cheol Park Nam Seo Goo Doyoung Byun Min Jun Kim | 2012 | Journal of Bionic Engineering2012,9,4: | 16 |
| 3 | Predictors of pain resolution after varicocelectomy for painful varicocele显示文摘Varicocelectomy 是为有痛苦的精索静脉曲张的病人的一种管理选择。在这研究,我们为痛苦的精索静脉曲张估计了 varicocelectomy 的有效性并且检验了可能结果预兆的因素。为在 2007 年 2 月和 2009 年 7 月之间的疼痛经历了 varicocelectomy 的所有病人被包括。耐心的医药记录的评论被进行;疼痛的耐心的年龄,身体团索引(BMI ) ,等级,精索静脉曲张的地点,阴囊的卷,持续时间和质量(迟钝,拖,跳动或锋利) 并且外科的技术(腹股沟对 subinguinal ) 被记录。所有参数与疼痛的决定相比(完全,部分或失败) 。我们列在后面在上面在 104 个病人中的 53 个上(51.0 %) 。疼痛的完全的手术后的分辨率被 28 个病人报导(52.8 %) ,而 22 (41.5 %) 报导部分分辨率。仅仅三个病人(5.7 %) 报导失败。没有关系在手术后的疼痛分辨率和年龄之间被观察, BMI,精索静脉曲张的等级,精索静脉曲张的地点, ipsilateral 阴囊的 hypotrophy,疼痛的质量或外科的技术。在外科前的疼痛的持续时间是与手术后的疼痛分辨率相关的唯一的因素(univariate, P=0.004;multivariate, P=0.002 ) 。我们的结果显示 varicocelectomy 是为在适当地选择的病人的痛苦的精索静脉曲张的有效治疗,并且在外科前的疼痛的那持续时间可能结果是预兆的。 | Hyun Jun Park Seung Soo Lee Nam Cheol Park | 2011 | Asian Journal of Andrology2011,13,5: | 14 |
| 4 | Prevalence of Primary and Secondary Antimicrobial Resistance of H elicobacter pylori in K orea from 2003 through 2012显示文摘 | Jung Won Lee Nayoung Kim Jung Mogg Kim Ryoung Hee Nam Hyun Chang Jae Yeon Kim Cheol Min Shin Young Soo Park Dong Ho Lee Hyun Chae Jung | 2012 | Helicobacter2012,,3: | 12 |
| 5 | Sandwich-structure transferable free-form OLEDs for wearable and disposable skin wound photomedicine显示文摘Free-form optoelectronic devices can provide hyper-connectivity over space and time.However,most conformable optoelectronic devices can only be fabricated on flat polymeric materials using low-temperature processes,limiting their application and forms.This paper presents free-form optoelectronic devices that are not dependent on the shape or material.For medical applications,the transferable OLED(10μm)is formed in a sandwich structure with an ultra-thin transferable barrier(4.8μm).The results showed that the fabricated sandwich-structure transferable OLED(STOLED)exhibit the same high-efficiency performance on cylindricalshaped materials and on materials such as textile and paper.Because the neutral axis is freely adjustable using the sandwich structure,the textile-based OLED achieved both folding reliability and washing reliability,as well as a long operating life(>150 h).When keratinocytes were irradiated with red STOLED light,cell proliferation and cell migration increased by 26 and 32%,respectively.In the skin equivalent model,the epidermis thickness was increased by 39%;additionally,in organ culture,not only was the skin area increased by 14%,but also,reepithelialization was highly induced.Based on the results,the STOLED is expected to be applicable in various wearable and disposable photomedical devices. | Yongmin Jeon Hye-Ryung Choi Jeong Hyun Kwon Seungyeop Choi Kyung Mi Nam Kyoung-Chan Park Kyung Cheol Choi | 2019 | Light(Science & Applications)2019,8,1: | 9 |
| 6 | Efficacy and safety of limited endoscopic sphincterotomy before self-expandable metal stent insertion for malignant biliary obstruction显示文摘AIM To evaluate the safety and efficacy of limited endoscopic sphincterotomy (ES) before placement of selfexpandable metal stent(SEMS).METHODS This was a retrospective analysis of 244 consecutive patients with unresectable malignant biliary obstruction, who underwent placement of SEMSs following limited ES from December 2008 to February 2015. The diagnosis of malignant biliary obstruction and assessment of patient eligibility for the study was established by a combination of clinical findings, laboratory investigations, imaging and pathological results. All patients were monitored in the hospital for at least 24 h following endoscopic retrograde cholangio pancreatography(ERCP). The incidence of immediate or early post-ERCP complications such as post-ERCP pancreatitis(PEP) and bleeding related to limited ES were considered as primary outcomes. Also, characteristics and complications according to the cancer type were classified.RESULTS Among the 244 patients included, the underlying diagnosis was cholangiocarcinoma in 118 patients,pancreatic cancer in 79, and non-pancreatic or nonbiliary malignancies in the remaining 47 patients. Early post-ERCP complications occurred in 9 patients(3.7%), with PEP in 7 patients (2.9%; mild, 6; moderate, 1) and mild bleeding in 2 patients (0.8%). There was no significant association between the incidence of post-ERCP complications and the type of malignancy(cholangiocarcinoma vs pancreatic cancer vs others, P = 0.696) or the type of SEMS used (uncovered vs covered, P = 1.000). Patients who had more than one SEMS placed at the first instance were at a significantly higher risk of post-ERCP complications (one SEMS vs two SEMS, P = 0.031). No other factors were predictive of post-ERCP complications.CONCLUSION Limited ES is feasible and safe, and effectively facilitates the placement of SEMS, without any significant risk of PEP or severe bleeding. | Hyeong Seok Nam Dae Hwan Kang Hyung Wook Kim Cheol Woong Choi Su Bum Park Su Jin Kim Dae Gon Ryu | 2017 | World Journal of Gastroenterology2017,23,9: | 7 |
| 7 | Is endoscopic ultrasonography essential for endoscopic resection of small rectal neuroendocrine tumors?显示文摘AIM To evaluate the importance of endoscopic ultrasonography(EUS) for small(≤ 10 mm) rectal neuroendocrine tumor(NET) treatment.METHODS Patients in whom rectal NETs were diagnosed by endoscopic resection(ER) at the Pusan National University Yangsan Hospital between 2008 and 2014 were included in this study. A total of 120 small rectal NETs in 118 patients were included in this study. Histologic features and clinical outcomes were analyzed, and the findings of endoscopy, EUS and histology were compared. RESULTS The size measured by endoscopy was not significantly different from that measured by EUS and histology(r = 0.914 and r = 0.727 respectively). Accuracy for the depth of invasion was 92.5% with EUS. No patients showed invasion of the muscularis propria or metastasis to the regional lymph nodes. All rectal NETswere classified as grade 1 and demonstrated an L-cell phenotype. Mean follow-up duration was 407.54 ± 374.16 d. No patients had local or distant metastasis during the follow-up periods. CONCLUSION EUS is not essential for ER in the patient with small rectal NETs because of the prominent morphology and benign behavior. | Su Bum Park Dong Jun Kim Hyung Wook Kim Cheol Woong Choi Dae Hwan Kang Su Jin Kim Hyeong Seok Nam | 2017 | World Journal of Gastroenterology2017,23,11: | 7 |
| 8 | Improvement of Artificial Foldable Wing Models by Mimicking the Unfolding/Folding Mechanism of a Beetle Hind Wing显示文摘In an attempt to realize a flapping wing micro-air vehicle with morphing wings, we report on improvements to our previousfoldable artificial hind wing.Multiple hinges, which were implemented to mimic the bending zone of a beetle hind wing, weremade of small composite hinge plates and tiny aluminum rivets.The buck-tails of rivets were flared after the hinge plates wereassembled with the rivets so that the folding/unfolding motions could be completed in less time, and the straight shape of theartificial hind wing could be maintained after fabrication.Folding and unfolding actions were triggered by electrically-activatedShape Memory Alloy (SMA) wires.For wing folding, the actuation characteristics of the SMA wire actuator were modifiedthrough heat treatment.Through a series of flapping tests, we confirmed that the artificial wings did not fold back and arbitrarilyfluctuate during the flapping motion. | Azhar Muhammad Quoc Viet Nguyen Hoon Cheol Park Do Y.Hwang Doyoung Byun Nam Seo Goo | 2010 | Journal of Bionic Engineering2010,7,2: | 6 |
| 9 | 韩国中年男性血清25-羟维生素D水平与皋酮缺乏:一项横向研究显示文摘原先的研究证明,男性性腺机能减退与维生素D低水平有关。然而,有关韩国男性维生素D对睾酮水平影响的研究尚未见报道。本研究的目的在于探讨睾酮的水平是否与血清维生素D水平相关,以及是否存在季节性变化。本横向研究分析了652名40岁以上韩国男性的血清25.羟维生素D[25(OH)D]、总睾酮(TT)以及游离睾酮(FT)水平。这些男性都经过了全面的体检。受试者的平均年龄56.7±7.9岁,平均血清血25.羟维生素D、总睾酮以及游离睾酮水平分别为21.23±7.9ngml-1,4.70±1.6ngml-1和8.12±3.3pgml-1。在多元线性回归模型,25.羟维生素D与总睾酮水平(B=O.137,P〈O.001)以及游离睾酮水平(B=0.103,P=O.008)呈现正相关。在调整了年龄因素之后,25.羟维生素D与游离睾酮水平之间呈现相似的季节性变化或月变化。在调整了年龄、季节、体重指数、身体成分、慢性疾病、吸烟以及饮酒等因素之后,维生素D缺乏[25(OH)D〈20ngml-1]与总睾酮水平缺乏(〈2.30ngml-1)的风险增高(风险率[OR]:2.65;95%可信区间:1.21—5.78,P=0.014)以及游离睾酮水平缺乏(〈6.50Pgml-1)的风险增高(OR:1.44;95%可信区间:1.01-2.06,P=O.048)相关。综上所述,我们证明了韩国男性血清25.羟维生素D与睾酮水平之间的正相关,并呈现季节性波动。 | Young Jin Tak Jeong Gyu Lee Yun Jin Kim Nam Cheol Park Sang Soo Kim Sangyeoup Lee Byung Mann Cho Eun Hee Kong Dong Wook Jung Yu Hyeon Yi | 2015 | Asian Journal of Andrology2015,17,2: | 5 |
| 10 | Prevalence of premature ejaculation in young and middle-aged men in Korea: a multicenter intemet-based survey from the Korean Andrological Society显示文摘 | Hyun Jun Park Jong Kwan Park Kwangsung Park Sung Won Lee Sae-Woong Kim Dae Yul Yang DU Geon Moon Kweon-Sik Min Ki-Hak Moon Sang-Kuk Yang Jae Seog Hyun Nam Cheol Park | 2010 | Asian Journal of Andrology2010,12,6: | 5 |
| 11 | 精索静脉曲张诱导的大鼠不育模型中E—cadherin和α—catenin在的表达显示文摘评价精索静脉曲张诱导的不育发展过程中E—cadhering和α-catenin的作用。本文分析了E—cadherin/α—catenin的表达与临床/病理参数之间的关联。取30只10周龄雄性大鼠,将左肾静脉结扎后致精索静脉曲张模型,作为实验组。取30只大鼠腹部切开处理作为对照组,取10只大鼠未做处理,作为基线组。分别记录各组大鼠4周和8周后的左睾丸的重量,血清中活性氧(ROS),睾酮,促黄体激索(LH),促卵泡激素(FSH)和生精小管的退行性改变。采用免疫组织化学法OHC)染色色Westernblot法分析E—cadherin和α—catenin的表达。与对照组和基线组相比,8周后实验组ROS增加(两组均P〈0.001)。此外,与对照组相比,478(P=0.013)和8周(P=0.032)后实验组的FSH显著增加。所有实验组中大鼠生精小管发生退行性改变的比例增加。免疫组织化学染色法的结果表明,4周和8周的实验组中E—cadherin和α-catenin的表达有所下降。Westernblot法的实验结果与免疫组化法的实验结果相近。E—eadherin和α—catenin的表达与ROS和生精小管的退行性改变是密切相关的。实验结果表明,血睾屏障(BTB)的损伤与精索静脉曲张诱导的男性不育有相关性,ROS可能会损坏血睾屏障。 | Hong Koo Ha Hyun Jun Park Nam Cheol Park | 2011 | Asian Journal of Andrology2011,13,3: | 5 |
| 12 | Free radical scavenger effect of rebamipide in sperm processing and cryopreservation显示文摘Alm:To study the effect of rebamipide added to semen samples and cryoprotectant on reactive oxygen species (ROS) production. Methods: Semen samples from 30 fertile and healthy volunteers were collected bymasturbation after 2 days-3 days of abstinence. After liquefaction, the specimens were diluted with sperm washmedia to a uniform density of 20×10^6/mL. Rebamipide was added to semen samples and cryoprotectant to a final concentration of 10μmol/L, 30μmol/L, 100μmol/L or 300μmol/L. Specimens were incubated at 37℃ in a 0.5 % CO2 incubator for I h or cryopreserved at -196℃ LN2 for 3 days. The sperm motility and viability and the levels of ROS and lipid peroxidation of sperm membrance were assessed before and after incubation and cryopreservation by means of computer assisted semen analyzer, eosin-nigrosin stain, chemiluminescence and thiobarbituric acid assay,respectively. Results: The sperm motility was significantly increased after incubation with 100 gmol/L and 300gmol/L rebamipide (P<0.05). After cryopreservation, the sperm motility was significantly decreased in all concentra-tions (P<0.05), but the decrease was less with 100μmol/L and 300μmol/L rebamipide than that with otherconcentrations. The sperm viability showed no significant difference before and after incubation (P>0.05). The levels of ROS and lipid peroxidation in semen were significantly decreased in proportion to the concentrations of rebamipide both after incubation and cryopreservation (P<0.05). Conclusion: Rebamipide is an effective flee radical scavenger in semen in vitro. ( Asian J Androl 2003 Sep; 5: 195-201) | Nam Cheol Park Hyun Jun Park Kyeong Mi Lee Dong Gil Shin | 2003 | Asian Journal of Andrology2003,5,3: | 4 |
| 13 | Effects of Korean Red Ginseng on Semen Parameters in Male Infertility Patients:A Randomized,Placebo-Controlled,Double-Blind Clinical Study显示文摘Objective: To investigate the effects of Korean red ginseng(KRG) on semen parameters in male infertility patients in a randomized, double-blind, placebo-controlled study. Methods: A total of 80 male infertility patients with varicocele were recruited from April 2011 to February 2012. The subjects were then divided into the following four groups: non-varicocelectomy(V)+placebo(P) group, V+P group, non-V+KRG group(1.5-g KRG daily), and V+KGR group(1.5-g KRG daily). Semen analysis was performed and hormonal levels were measured in each treatment arm after 12 weeks. Results: All groups but not the non-V+P group, showed significant improvements in sperm concentrations, motility, morphology, and viability at the end of the study. However, there were no significant differences in serum follicle-stimulating hormone, luteinizing hormone, and testosterone among groups. The incidence of adverse events was low, and all events were assumed to be unrelated to the treatments administered. Conclusions: Although the exact mechanism by which KRG improves spermatogenesis remains unclear, KRG may be a useful agent for the treatment of male infertility. Nevertheless, additional studies to evaluate the optimal dose and duration of treatment are needed. | Hyun Jun Park Sangmin Choe Nam Cheol Park | 2016 | Chinese Journal of Integrative Medicine2016,22,7: | 4 |
| 14 | The Role of Elytra in Beetle Flight: Ⅰ.Generation of Quasi-Static Aerodynamic Forces显示文摘We conducted a comprehensive study to investigate the aerodynamic characteristics and force generation of the elytra of abeetle,Allomyrina dichotoma.Our analysis included wind tunnel experiments and three-dimensional computational fluiddynamics simulations using ANSYS-CFX software.Our first approach was a quasi-static study that considered the effect ofinduced flapping flow due to the flapping motion of the fore-wings (elytra) at a frequency of around 30 Hz to 40 Hz.The dihedralangle was varied to represent flapping motion during the upstroke and downstroke.We found that an elytron producespositive lift at 0° geometric angle of attack,negative lift during the upstroke,and always produces drag during both the upstrokeand downstroke.We also found that the lift coefficient of an elytron does not drop even at a very high geometric angle of attack.For a beetle with a body weight of 5 g,based on the quasi-static method,the fore-wings (elytra) can produce lift of less than 1%of its body weight. | Patar Ebenezer Sitorus Hoon Cheol Park Doyoung Byun Nam Seo Goo Cheol Heui Han | 2010 | Journal of Bionic Engineering2010,7,4: | 4 |
| 15 | Advantage of endoscopic mucosal resection with a cap for rectal neuroendocrine tumors显示文摘AIM: To compare the outcomes of endoscopic mucosal resection with a cap(EMR-C) with those of endoscopic submucosal dissection(ESD) for the resection of rectal neuroendocrine tumors.METHODS: One hundred and sixteen lesions in 114 patients with rectal neuroendocrine tumor(NET) resected with EMR-C or ESD were included in the study. This study was performed at Pusan National University Yangsan Hospital between July 2009 and August 2014. We analyzed endoscopic complete resection rate,pathologic complete resection rate,procedure time,and adverse events in the EMR-C(n = 65) and ESD(n = 51) groups. We also performed a subgroup analysis by tumor size.RESULTS: Mean tumor size was 4.62 ± 1.66 mm in the EMR-C group and 7.73 ± 3.14 mm in the ESD group(P < 0.001). Endoscopic complete resection rate was 100% in both groups. Histologic complete resection rate was significantly greater in the EMR-C group(92.3%) than in the ESD group(78.4%)(P = 0.042). Mean procedure time was significantly longer in the ESD group(14.43 ± 7.26 min) than in the EMR-C group(3.83 ± 1.17 min)(P < 0.001). Rates of histologic complete resection without complication were similar for tumor diameter ≤ 5 mm(EMR-C,96%; ESD,100%,P = 0.472) as well as in cases of 5 mm < tumor diameter ≤ 10 mm(EMR-C,80%; ESD,71.0%,P = 0.524).CONCLUSION: EMR-C may be simple,faster,and more effective than ESD in removing rectal NETs and may be preferable for resection of small rectal NETs. | Su Bum Park Hyung Wook Kim Dae Hwan Kang Cheol Woong Choi Su Jin Kim Hyeong Seok Nam | 2015 | World Journal of Gastroenterology2015,21,31: | 4 |
| 16 | Use of a Digital Image Correlation Technique for Measuring the Material Properties of Beetle Wing显示文摘Beetle wings are very specialized flight organs consisting of the veins and membranes.Therefore it is necessary from abionic view to investigate the material properties of a beetle wing experimentally.In the present study,we have used a DigitalImage Correlation (DIC) technique to measure the elastic modulus of a beetle wing membrane.Specimens were prepared bycarefully cutting a beetle hind wing into 3.0 mm by 7.0 mm segments (the gage length was 5 mm).We used a scanning electronmicroscope for a precise measurement of the thickness of the beetle wing membrane.The specimen was attached to a designedfixture to induce a uniform displacement by means of a micromanipulator.We used an ARAMISTM system based on the digitalimage correlation technique to measure the corresponding displacement of a specimen.The thickness of the beetle wing variedat different points of the membrane.The elastic modulus differed in relation to the membrane arrangement showing a structuralanisotropy;the elastic modulus in the chordwise direction is approximately 2.65 GPa,which is three times larger than the elasticmodulus in the spanwise direction of 0.84 GPa.As a result,the digital image correlation-based ARAMIS system was suc-cessfully used to measure the elastic modulus of a beetle wing.In addition to membrane’s elastic modulus,we considered thePoisson’s ratio of the membrane and measured the elastic modulus of a vein using an Instron universal tensile machine.Theresult reveals the Poisson’s ratio is nearly zero and the elastic modulus of a vein is about 11 GPa. | Tailie Jin Nam Seo Goo Sung-Choong Woo Hoon Cheol Park | 2009 | Journal of Bionic Engineering2009,6,3: | 4 |
| 17 | Treatment preferences in men with erectile dysfunction: an open label study in Korean men switching from sildenafil citrate to tadalafil显示文摘瞄准:为 sildenafil 柠檬酸盐或 tadalafil 评估耐心的偏爱(为可勃起的机能障碍的治疗可得到的 PDE-5 禁止者[编辑]) 并且为这些偏爱估计潜在的原因。方法:这开标签的研究在拿 sildenafil 的朝鲜的人,上被进行在学习入口以前的至少 6 个星期为编辑追随者屏蔽,病人们继续 sildenafil 治疗 4 个星期,然后在一个 1 星期的冲刷时期以后,换到 tadalafil 8 个星期。病人们然后在一个延期阶段期间继续了他们选择的治疗。Psychosocial 因素(时间担心,自然,性自信) 用心理、人与人之间的关系规模(对) 被评估,当剂量预定到性尝试时,模式从耐心的日记被估计。结果:现在的学习注册了 160 个朝鲜的人(意味着年龄 55 年) 与 585 天的优先的中部的 sildenafil 使用。在延期阶段期间, 73.7% 病人选择拿 tadalafil,而 26.3% 选择了 sildenafil (P < 0.001 ) 。在从 sildenafil 切换到 tadalafil 以后,意味着担心分数从 2.54 ~ 2.42 减少了的对时间(P = 0.002 ) ,没有统计上,有效差量在性自然和自信分数在 sildenafil 和 tadalafil 评价阶段之间观察了。做的性尝试 < 4 h 到≤ 36 h 剂量以后在 tadalafil 评价阶段期间与 17.5% 相比在 sildenafil 评价阶段期间发生在 4.5% 病人。结论:在经历 sildenafil 和 tadalafil 以后,病人的多数为 tadalafil 展出了偏爱。这偏爱可能被精神分析聚会因素影响,例如减少的时间担心,和为性欲活动可得到的机会的一扇更宽广的窗户。 | Tai Young Ahn Sung Won Lee Sae-Woong Kim Dae Yul Yang Nam Cheol Park Kweon-Sik Min Kwangsung Park Jae-Seung Paick Yulia Dyachkova Trisha Dwight Myung-Sea Luke Lee | 2007 | Asian Journal of Andrology2007,9,6: | 3 |
| 18 | Structural Characteristics of Allomyrina Dichotoma Beetle's Hind Wings for Flapping Wing Micro Air Vehicle显示文摘 | Ngoc San Ha Quang Tri Truong Hoang Vu Phan Nam Seo Goo Hoon Cheol Park | 2014 | Journal of Bionic Engineering2014,11,2: | 3 |
| 19 | Assessment of disease activity by fecal immunochemical test in ulcerative colitis显示文摘AIM To evaluate the efficacy of quantitative fecal immunochemical test(FIT) as biomarker of disease activity in ulcerative colitis(UC).METHODS Between February 2013 and November 2014, a total of 82 FIT results, obtained in conjunction with colonoscopies, were retrospectivelyevaluated for 63 patients with UC. The efficacy of FIT for evaluation of disease activity was compared to colonoscopic findings. Quantitative fecal blood with automated equipment examined from collected feces. Endoscopic disease severity were assessed using the Mayo endoscopic subscore(MES) classification. The extent of disease were classified by proctitis(E1), left sided colitis(E2), and extensive colitis(E3). Clinical activity were subgrouped by remission or active.RESULTS All of 21 patients with MES 0 had negative FIT(< 7 ng/mL), but 22 patients with MES 2 or 3 had a mean FIT of > 134.89 ng/m L. The sensitivity, specificity, positive predictive value(PPV), negative predictive value(NPV) and accuracy of negative FIT about mucosal healing were 73.33%, 81.82%, 91.49%, 51.43% and 73.17%, respectively. The sensitivity, specificity, PPV, NPV and accuracy of predictive value of positive FIT(cutoff value > 100 ng/mL) about active disease status were 45.45%, 93.33%, 71.43%, 82.35%and 26.83%, respectively. Among patients with clinical remission, FIT was negative in 31(81.6%) of 38 cases, with a mean fecal hemoglobin concentration of 6.12 ng/mL(range, negative to 80.9 ng/mL) for this group of patients. Among patients with clinical active disease, FIT was negative in 16(36.4%) out of 44 cases, with a mean fecal hemoglobin concentration > 167.4 ng/mL for this group of patients. FIT was positively correlated with endoscopic activity(r = 0.626, P < 0.01) and clinical activity(r = 0.496, P < 0.01). But, FIT did not correlate with the extent of disease(r =-0.047, P = 0.676)CONCLUSION Quantitative FIT can be a non-invasive and effective biomarker for evaluation of clinical and endoscopic activity in UC, but not predict the extent of disease. | Dae Gon Ryu Hyung Wook Kim Su Bum Park Dae Hwan Kang Cheol Woong Choi Su Jin Kim Hyeong Seok Nam | 2016 | World Journal of Gastroenterology2016,22,48: | 3 |
| 20 | Multi-directionally wrinkle-able textile OLEDs for clothing-type displays显示文摘A clothing-type wearable display can be utilized in fashion,bio-healthcare,and safety industries as well as smart textiles for the internet of things(IoTs)and wearable devices.In response to this trend,we demonstrate a textile display that can endure the active movements of a human body.It can be applied to any kind of textile,and is durable against conditions such as rain,sweat,and washing.As a key technology for realizing the multi-directional wrinkle-able textile display,we fabricated a stress-lowering textile platform with an ultrathin planarization layer replicated from the flat surface of glass.An elastomeric strain buffer for reducing mechanical stress is also inserted into the textile platform.Here,organic light-emitting diodes(OLEDs)with red,green and blue color,thin film transistors(TFTs)fabricated at a low temperature below 150℃,and a washable encapsulation layer blocking both gas and liquid were demonstrated on the textile platform. | Seungyeop Choi Woosung Jo Yongmin Jeon Seonil Kwon Jeong Hyun Kwon Young Hyun Son Junmo Kim Jun Hong Park Hyuncheol Kim Ho Seung Lee Minwoo Nam Eun Gyo Jeong Jeong Bin Shin Taek-Soo Kim Kyung Cheol Choi | 2020 | npj Flexible Electronics2020,4,1: | 3 |