|
|
|
题名
|
作者
|
年代
|
出处
|
被引量
|
| 1 | DFT study of difference caused by catalyst supports in Pt and Pd catalysis of oxygen reduction reaction显示文摘Based on an experimental phenomenon that catalytic activity of Pt and Pd for oxygen reduction reaction (ORR) changes with catalyst supports from C to TiO2, density function theory (DFT) was used to elucidate the cause behind the difference in catalysis caused by catalyst supports. First, factors closely associated with the first electron transfer of the ORR were assessed in the light of quantum chemistry. Then intermediate (atomic oxygen, O) adsorption strength on the catalyst surface was calculated. The results show that, in terms of minimum energy difference, the best orbital symmetry match, and the maximum orbital overlap, TiO2 does bring about a very positive effect on catalysts Pd/TiO2 for the first electron transfer of the ORR. Especially, TiO2 remarkably expands the space size of Pd/TiO2 HOMO orbital and improves orbital overlap of Pd/TiO2 HOMO and O2 LUMO. The analysis of deformation density and partial density of state shows that the strong interaction between Pt and Ti leads to a strong adsorption of intermediate O on Pt/TiO2, but the strong interaction between Pd and surface O causes positive net charge of Pd and a weak adsorption of intermediate O on Pd/TiO2. Thus, the ORR can proceed more smoothly on Pd/TiO2 than Pt/TiO2 in every respect of maximum orbital overlap and rate delay by intermediate O. The research also discloses that several factors lead to less activity of TiO2-supported Pt and Pd catalysts than the C-supported ones for the ORR. These factors include the poor dispersion of Pt and Pd particles on TiO2, poor electric conduction of TiO2 carrier itself, and bigger energy difference between HOMO of TiO2-carried metallic catalysts and LUMO of O2 molecule due to electrons deeply embedded in the semiconductor TiO2 carrier. | LI Li WEI ZiDong ZHANG Yi QI XueQiang XIA MeiRong ZHANG Jie SHAO ZhiGang SUN CaiXin | 2009 | Science China Chemistry2009,52,5: | 6 |
| 2 | Influence of Vegetable Oil on the Thermal Aging Rate of Kraft Paper and its Mechanism显示文摘 | YANG Lijun DENG Bangfei LIAO Ruijin SUN Caixin ZHU Mengzhao | 2012 | 高电压技术2012,38,8: | 4 |
| 3 | Chemical oscillation in electrochemical oxidation of methanol on Pt surface显示文摘Based on dual path reaction mechanism, a nonlinear dynamics model reflecting the potential oscilla- tion in electrooxidation of methanol on Pt surface was established. The model involves three variables, the electrode potential (e), the surface coverage of carbon monoxide (x), and adsorbed water (y). The chemical reactions and electrode potential were coupled together through the rate constant ki = exp(ai(e ? ei)). The analysis to the established model discloses the following: there are different kinetics be- haviors in different ranges of current densities. The chemical oscillation in methanol electrooxidation is assigned to two aspects, one from poison mediate CO of methanol electrooxidation, which is the in- duced factor of the chemical oscillation, and the other from the oxygen-containing species, such as H2Oa. The formation and disappearance of H2Oa deeply depend on the electrode potential, and directly cause the chemical oscillation. The established model makes clear that the potential oscillation in methanol electrooxidation is the result of the feedback of electrode potential e on the reactions in- volving poison mediates CO and oxygen-containing species H2Oa. The numerical analysis of the estab- lished model successfully explains why the potential oscillation in methanol galvanostatic oxidation on a Pt electrode only happens in a certain range of current densities but not at any current density. | LI LanLan WEI ZiDong QI XueQiang SUN CaiXin YIN GuangZhi | 2008 | Science China Chemistry2008,51,4: | 3 |
| 4 | Inhibiting Ice Accumulation on Conductors by Using Sheath Treated with Super-hydrophobic Surfaces显示文摘Ice accumulation on transmission lines often leads to great damage to power systems.Super-hydrophobic surfaces are proposed to inhibit ice accumulation on electrical power equipment.A novel anti-icing method was presented for conductors with super-hydrophobic sleeves.The super-hydrophobic sleeves were prepared by applying polydimethylsiloxane(PDMS) and nano-silica hybrid coating on the outer surface of polyethylen terephthalate(PET) sleeves.Hydrophobicity and ice adhesion strength of the super-hydrophobic surface were investigated.Ice accumulation experiments were carried out on ordinary conductors,super-hydrophobic coated conductors,PET sleeve-covered conductors,and super-hydrophobic PET sleeve-covered conductors.Ice accumulation morphology,accumulated ice weight,and the icicle length of these four types of conductors were studied and analyzed.At the end of the 3 h ice accumulation experiment,the ice weight and icicle length on the conductor with super-hydrophobic PET sleeve was only approximately one tenth and one seventh of that on the untreated conductor respectively.Furthermore,the water contact angles of super-hydrophobic coated aluminum surface and super-hydrophobic coated PET sleeve were about 163o in average.The results indicate that the super-hydrophobic coating is effective in inhibiting ice accumulation on conductors.However,the use of a super-hydrophobic PET sleeve is a significantly more effective method,comparing with the application of a super-hydrophobic coating directly on the conductor. | LI Jian GONG Yiyu LI Yong HU Jianlin SUN Caixin XIAO Daibo | 2013 | 高电压技术2013,39,10: | 2 |
| 5 | Experimental studies on killing and inhibiting effects of steep pulsed electric field (SPEF) to target cancer cells and solid tumor显示文摘 | Yao Chenguo Sun Caixin Mi Yan | 2004 | IEEE Transactions on Plasma Science2004,32,4: | 1 |
| 6 | Flashover performance of pre-contaminated and ice-covered composite insulators to be used in 1 000 kV UHV AC transmission lines显示文摘 | Hu Jianlin Sun Caixin Jiang Xingliang | 2007 | IEEE Transactions on Dielectrics andElctrical Insulation2007,14,6: | 1 |
| 7 | Application of complex wavelet transform to suppress white noise in GIS UHF PD signals显示文摘 | Xu Zhongrong Tang Ju Sun Caixin | 2007 | IEEE Trans on Power Delivery2007,22,3: | 1 |
| 8 | Stage pre- warning based on leakage current characteristics before contamination flashover of porcelain and glass insulators 显示文摘 | LI Jingyan SUN Caixin SIMA Wenxia | 2009 | IET Generation Transmission & Distribution2009,3,7: | 1 |
| 9 | Application of complex wavelet transform to suppress white moise in GIS UHF PD signals显示文摘 | Xu Zhongrong Tang Ju Sun Caixin | 2007 | IEEE Transactions on Power Delivery2007,22,3: | 1 |
| 10 | Experimental studies on killing and inhibiting effects of steep pulsed electric field (SPEF) to target cancer cell and solid tumor显示文摘 | Chenguo Yao Caixin sun Yan Mi | 2004 | IEEE Transa on Plasma Science2004,32,4: | 1 |
| 11 | An imporved box-counting method for image fractal dimension estimation 显示文摘 | Li Jian Du Qian Sun Caixin | 2009 | Pattern Recognition2009,42,4: | 1 |
| 12 | Artificial immune network classi-fication algorithm for fault diagnosis of power transformer显示文摘 | Xiong Hao Sun Caixin | 2007 | IEEE Transactions on Power Delivery2007,22,7: | 1 |
| 13 | A new broadband micro-current transducer for insulator leakage current monitoring system显示文摘 | Chen Weigen Yao Chenguo Sun Caixin | 2008 | IEEE Transactions on Power Delivery2008,23,1: | 1 |
| 14 | The impact of humidity and contamination severity on the leakage currents of porcelain insulators显示文摘 | LI Jingyan SUN Caixin SEBO Stephen | 2009 | IET Proceedings Generation Transmission&Distribution2009,5,1: | 1 |
| 15 | Flashover performance of pre-contaminated and ice-covered composite insulators to be used in 1000 kV UHV AC transmission lines显示文摘 | Hu Jianlin Sun Caixin Jiang Xingliang | 2007 | IEEE Transactions on Dielectrics and Electrical Insulation2007,14,6: | 1 |
| 16 | RBF neural network and ANFIS-based short-term load forecasting approach in real-time price environment显示文摘 | ZHANG Yun ZHOU Quan SUN Caixin | 2008 | IEEE Transactions on Power Systems2008,23,3: | 1 |
| 17 | Study of flashover performance and voltage correction of DC insulator in icing districts of altitude of 2500m and below显示文摘 | Jiang Xingliang Sima Wenxia | 2002 | IWAIS 2002 Bmo Czech Republic2002,2002,: | 1 |
| 18 | Evaluating the Safety Condition of Porcelain Insulators by the Time and Frequency Characteristics of LC Based on Artificial Pollution Tests 显示文摘 | Xingliang Jiang Yan Shi Caixin Sun | 2010 | IEEE Transactions on Dielectrics and Electrical Insulation (S1070-9878)2010,17,2: | 1 |
| 19 | Flashover performance of pre-contaminated and ice-covered composite insulators to be used in 1000kV UHV AC transmission lines显示文摘 | Hu Jianlin Sun Caixin Jiang Xingliang | 2007 | IEEE Transactions on Dielectric and Electrical Insulation2007,14,6: | 1 |
| 20 | An improved box- counting method for imagefractal dimension estimati on 显示文摘 | Li Jian Du Qian Sun Caixin | 2009 | Pattern Recognition2009,42,11: | 1 |