维普中文期刊产品整合服务
78篇 您的检索式:作者名="SUN Caixin"
    题名 作者 年代 出处 被引量
1DFT study of difference caused by catalyst supports in Pt and Pd catalysis of oxygen reduction reaction显示文摘Based on an experimental phenomenon that catalytic activity of Pt and Pd for oxygen reduction reaction (ORR) changes with catalyst supports from C to TiO2, density function theory (DFT) was used to elucidate the cause behind the difference in catalysis caused by catalyst supports. First, factors closely associated with the first electron transfer of the ORR were assessed in the light of quantum chemistry. Then intermediate (atomic oxygen, O) adsorption strength on the catalyst surface was calculated. The results show that, in terms of minimum energy difference, the best orbital symmetry match, and the maximum orbital overlap, TiO2 does bring about a very positive effect on catalysts Pd/TiO2 for the first electron transfer of the ORR. Especially, TiO2 remarkably expands the space size of Pd/TiO2 HOMO orbital and improves orbital overlap of Pd/TiO2 HOMO and O2 LUMO. The analysis of deformation density and partial density of state shows that the strong interaction between Pt and Ti leads to a strong adsorption of intermediate O on Pt/TiO2, but the strong interaction between Pd and surface O causes positive net charge of Pd and a weak adsorption of intermediate O on Pd/TiO2. Thus, the ORR can proceed more smoothly on Pd/TiO2 than Pt/TiO2 in every respect of maximum orbital overlap and rate delay by intermediate O. The research also discloses that several factors lead to less activity of TiO2-supported Pt and Pd catalysts than the C-supported ones for the ORR. These factors include the poor dispersion of Pt and Pd particles on TiO2, poor electric conduction of TiO2 carrier itself, and bigger energy difference between HOMO of TiO2-carried metallic catalysts and LUMO of O2 molecule due to electrons deeply embedded in the semiconductor TiO2 carrier.LI Li WEI ZiDong ZHANG Yi QI XueQiang XIA MeiRong ZHANG Jie SHAO ZhiGang SUN CaiXin 2009Science China Chemistry2009,52,5:6
2Influence of Vegetable Oil on the Thermal Aging Rate of Kraft Paper and its Mechanism显示文摘YANG Lijun DENG Bangfei LIAO Ruijin SUN Caixin ZHU Mengzhao 2012高电压技术2012,38,8:4
3Chemical oscillation in electrochemical oxidation of methanol on Pt surface显示文摘Based on dual path reaction mechanism, a nonlinear dynamics model reflecting the potential oscilla- tion in electrooxidation of methanol on Pt surface was established. The model involves three variables, the electrode potential (e), the surface coverage of carbon monoxide (x), and adsorbed water (y). The chemical reactions and electrode potential were coupled together through the rate constant ki = exp(ai(e ? ei)). The analysis to the established model discloses the following: there are different kinetics be- haviors in different ranges of current densities. The chemical oscillation in methanol electrooxidation is assigned to two aspects, one from poison mediate CO of methanol electrooxidation, which is the in- duced factor of the chemical oscillation, and the other from the oxygen-containing species, such as H2Oa. The formation and disappearance of H2Oa deeply depend on the electrode potential, and directly cause the chemical oscillation. The established model makes clear that the potential oscillation in methanol electrooxidation is the result of the feedback of electrode potential e on the reactions in- volving poison mediates CO and oxygen-containing species H2Oa. The numerical analysis of the estab- lished model successfully explains why the potential oscillation in methanol galvanostatic oxidation on a Pt electrode only happens in a certain range of current densities but not at any current density.LI LanLan WEI ZiDong QI XueQiang SUN CaiXin YIN GuangZhi 2008Science China Chemistry2008,51,4:3
4Inhibiting Ice Accumulation on Conductors by Using Sheath Treated with Super-hydrophobic Surfaces显示文摘Ice accumulation on transmission lines often leads to great damage to power systems.Super-hydrophobic surfaces are proposed to inhibit ice accumulation on electrical power equipment.A novel anti-icing method was presented for conductors with super-hydrophobic sleeves.The super-hydrophobic sleeves were prepared by applying polydimethylsiloxane(PDMS) and nano-silica hybrid coating on the outer surface of polyethylen terephthalate(PET) sleeves.Hydrophobicity and ice adhesion strength of the super-hydrophobic surface were investigated.Ice accumulation experiments were carried out on ordinary conductors,super-hydrophobic coated conductors,PET sleeve-covered conductors,and super-hydrophobic PET sleeve-covered conductors.Ice accumulation morphology,accumulated ice weight,and the icicle length of these four types of conductors were studied and analyzed.At the end of the 3 h ice accumulation experiment,the ice weight and icicle length on the conductor with super-hydrophobic PET sleeve was only approximately one tenth and one seventh of that on the untreated conductor respectively.Furthermore,the water contact angles of super-hydrophobic coated aluminum surface and super-hydrophobic coated PET sleeve were about 163o in average.The results indicate that the super-hydrophobic coating is effective in inhibiting ice accumulation on conductors.However,the use of a super-hydrophobic PET sleeve is a significantly more effective method,comparing with the application of a super-hydrophobic coating directly on the conductor.LI Jian GONG Yiyu LI Yong HU Jianlin SUN Caixin XIAO Daibo 2013高电压技术2013,39,10:2
5Experimental studies on killing and inhibiting effects of steep pulsed electric field (SPEF) to target cancer cells and solid tumor显示文摘Yao Chenguo Sun Caixin Mi Yan 2004IEEE Transactions on Plasma Science2004,32,4:1
6Flashover performance of pre-contaminated and ice-covered composite insulators to be used in 1 000 kV UHV AC transmission lines显示文摘Hu Jianlin Sun Caixin Jiang Xingliang 2007IEEE Transactions on Dielectrics andElctrical Insulation2007,14,6:1
7Application of complex wavelet transform to suppress white noise in GIS UHF PD signals显示文摘Xu Zhongrong Tang Ju Sun Caixin 2007IEEE Trans on Power Delivery2007,22,3:1
8Stage pre- warning based on leakage current characteristics before contamination flashover of porcelain and glass insulators 显示文摘LI Jingyan SUN Caixin SIMA Wenxia 2009IET Generation Transmission & Distribution2009,3,7:1
9Application of complex wavelet transform to suppress white moise in GIS UHF PD signals显示文摘Xu Zhongrong Tang Ju Sun Caixin 2007IEEE Transactions on Power Delivery2007,22,3:1
10Experimental studies on killing and inhibiting effects of steep pulsed electric field (SPEF) to target cancer cell and solid tumor显示文摘Chenguo Yao Caixin sun Yan Mi 2004IEEE Transa on Plasma Science2004,32,4:1
11An imporved box-counting method for image fractal dimension estimation 显示文摘Li Jian Du Qian Sun Caixin 2009Pattern Recognition2009,42,4:1
12Artificial immune network classi-fication algorithm for fault diagnosis of power transformer显示文摘Xiong Hao Sun Caixin 2007IEEE Transactions on Power Delivery2007,22,7:1
13A new broadband micro-current transducer for insulator leakage current monitoring system显示文摘Chen Weigen Yao Chenguo Sun Caixin 2008IEEE Transactions on Power Delivery2008,23,1:1
14The impact of humidity and contamination severity on the leakage currents of porcelain insulators显示文摘LI Jingyan SUN Caixin SEBO Stephen 2009IET Proceedings Generation Transmission&Distribution2009,5,1:1
15Flashover performance of pre-contaminated and ice-covered composite insulators to be used in 1000 kV UHV AC transmission lines显示文摘Hu Jianlin Sun Caixin Jiang Xingliang 2007IEEE Transactions on Dielectrics and Electrical Insulation2007,14,6:1
16RBF neural network and ANFIS-based short-term load forecasting approach in real-time price environment显示文摘ZHANG Yun ZHOU Quan SUN Caixin 2008IEEE Transactions on Power Systems2008,23,3:1
17Study of flashover performance and voltage correction of DC insulator in icing districts of altitude of 2500m and below显示文摘 Jiang Xingliang Sima Wenxia 2002IWAIS 2002 Bmo Czech Republic2002,2002,:1
18Evaluating the Safety Condition of Porcelain Insulators by the Time and Frequency Characteristics of LC Based on Artificial Pollution Tests 显示文摘Xingliang Jiang Yan Shi Caixin Sun 2010IEEE Transactions on Dielectrics and Electrical Insulation (S1070-9878)2010,17,2:1
19Flashover performance of pre-contaminated and ice-covered composite insulators to be used in 1000kV UHV AC transmission lines显示文摘Hu Jianlin Sun Caixin Jiang Xingliang 2007IEEE Transactions on Dielectric and Electrical Insulation2007,14,6:1
20An improved box- counting method for imagefractal dimension estimati on 显示文摘Li Jian Du Qian Sun Caixin 2009Pattern Recognition2009,42,11:1
返回顶部 每页显示:
共4页 首页 上一页 第1页 下一页 末页 /4 跳转

网站首页 | 关于我们 | 联系我们 | 产品服务 | 客服中心 | 广告服务 | 版权声明 | 网站联盟 | 友情链接 | 售卡网点

版权所有© 渝B2-20050021-1 渝公网安备 50019002500403号 违法和不良信息举报中心

互联网出版许可证 新出网证(渝)字10号 全国400电话 - 免长途话费