维普中文期刊产品整合服务
16篇 您的检索式:作者名="Shizhe Song"
    题名 作者 年代 出处 被引量
1Review-material degradation assessed by digital image processing:Fundamentals,progresses,and challenges显示文摘Material degradation is accompanied by the changes in surface structure,morphology,and composition.These changes can be recorded by a variety of image acquisition devices that export digital images in grayscale or true color to a detector.Information regarding corrosion type and extent can be extracted with image processing methods.This paper provides a comprehensive review of material degradation assessed by digital image processing.Digital image processing systems used to assess material degradation are briefly reviewed,and the algorithms developed to process metallic materials degradation images are described.Physical and electrochemical methods that can be used to support digital image processing results are summarized,and future work that will augment the present methods of evaluating material degradation are discussed.Da-Hai Xia Shizhe Song Lei Tao Zhenbo Qin Zhong Wu Zhiming Gao Jihui Wang Wenbin Hu Yashar Behnamian Jing-Li Luo 2020Journal of Materials Science & Technology2020,52,18:8
2Electrochemical measurements used for assessment of corrosion and protection of metallic materials in the field:A critical review显示文摘Corrosion degradation is detrimental to metal structures as it shortens their lifetime and leads to huge economic losses and unexpected disasters.Therefore,the detection and monitoring of corrosion degradation is of great importance.Herein,we briefly review the state-of-the-art electrochemical methods,instrumentation(based on virtual instrumentation),and advanced sensor/probes that are used in the field for the assessment of corrosion damage.Typical corrosion monitoring results,some of which have been obtained at Tianjin University in the past 30 years,for metallic materials and organic coating/metal systems in atmospheric,marine,and soil conditions in the field are presented.Detection methods,data analysis,and theoretical and mathematical models regarding each corrosion system are discussed,and the challenges,problems and possible solutions for each case are suggested.Lastly,future developments,such as wireless,intelligent,and automatic electrochemical measurement,that will augment the present electrochemical methods of evaluating corrosion degradation are summarized.Da-Hai Xia Cheng-Man Deng Digby Macdonald Sina Jamali Douglas Mills Jing-Li Luo Michael G.Strebl Mehdi Amiri Weixian Jin Shizhe Song Wenbin Hu 2022Journal of Materials Science & Technology2022,,17:8
3Degradation Mechanism of Lacquered Tinplate in Energy Drink by in-situ EIS and EN显示文摘The corrosion process of phenolic epoxy coated tinplate in energy drink was investigated by in-situ electrochemical impedance spectroscopy(EIS) and electrochemical noise(EN) techniques. The experimental results indicate that the degradation process of novolac epoxy coated tinplate in energy drink can be divided into three main stages: organic coating wetted by the beverage; corrosion initiation beneath the organic coating; and corrosion extension process. It was proposed that the tin coating and carbon steel were mainly corroded by organic acids in energy drink through the pores of the organic coating. After the tin coating was corroded, the carbon steel started to corrode due to its higher electrochemical activity and became to be the dominated corrosion reaction.周超 WANG Jihui SONG Shizhe 夏大海 WANG Ke SHEN Chen LUO Bing SHI Jiangbo 2013Journal of Wuhan University of Technology(Materials Science)2013,28,2:3
4Enhancing the Stability of Passive Film on 304 SS by Chemical Modification in Alkaline Phosphate–Molybdate Solutions显示文摘The purpose of this work was to enhance the corrosion resistance of the passive fi lm on 304 stainless steel(SS)by chemical modifi cation in alkaline phosphate–molybdate solutions.The 304 SS was passivated in both phosphate and phosphate–molybdate mixed solutions to investigate the eff ect of molybdate on its corrosion resistance.The experimental results indicated that the passive fi lm showed better corrosion resistance in Cl?-containing solutions after modifi cation in phosphate–molybdate solutions than in phosphate-only solutions.Energy-dispersive spectroscopy analyses revealed that the passive fi lm formed in phosphate–molybdate solutions contained Mo and P after modifi cation,which is the reason for the enhanced corrosion resistance.Chengcheng Pan Yang Song Weixian Jin Zhenbo Qin Shizhe Song Wenbin Hu Da-Hai Xia 2020Transactions of Tianjin University2020,26,2:2
5Quantifi cation of the Atmospheric Corrosion of 304 and 2205 Stainless Steels Using Electrochemical Probes Based on Thevenin Electrochemical Equivalent Circuit Model显示文摘Stainless steel(SS)is one of the most widely used engineering materials in marine engineering.However,its corrosion in the marine atmospheric environment due to the high concentration of Cl-is a problem.The SS corrosion is a threat to the development and security of marine industry;therefore,evaluating the corrosion resistance of SSs is necessary.In this work,atmospheric corrosion detection probes based on a symmetrical electrode system were used to study the corrosion behaviors of 304 SS and 2205 duplex stainless steel(DSS)in a simulated marine atmosphere.A theoretical model for electrochemical noise(EN)data analysis based on the Thevenin electrochemical equivalent circuit(EEC)model was established.The relationship between the EN characteristic parameters and the corrosion rate was obtained.The Thevenin EEC model analysis showed that the relationship between the noise resistance(Rn),the noise impedance[Rsn(f)],and the impedance modulus(|Z(f)|)was Rn≈Rsn=■.Thus,Rn and Rsn can be used as indicators for quantitative corrosion evaluation.The results of EN detection for the 304 SS and 2205 DSS showed that in a simulated marine atmospheric environment,the passive fi lms on the two SSs were relatively intact at the initial exposure stage,and their dissolution rates were slow.The corrosion resistance of the 2205 DSS was higher than that of the 304 SS.With the deposition of Cl-on the SS surface,pitting was initiated and the dissolution rate increased.The pitting initiation process on the SS surface was random,and part of the active pores could be repassivated.Yu Zhu Yang Song Likun Xu Zhenbo Qin Shizhe Song Wenbin Hu Da-Hai Xia 2020Transactions of Tianjin University2020,26,3:2
6Preparation and Characterization of the Modified Polyvinylidene Fluoride (PVDF) Hollow Fibre Microfiltration Membrane显示文摘一种新奇热地导致的接枝聚合技术被用来修改 apolyvinylidene 氟化物( PVDF )空纤维 microfiltration membrane.An 人工的 neuralnetwork ( ANN )被使用优化 membrane.The 的准备条件优化 dosing ofacrylic 酸( AA ), acrylamide ( AM ), N , N “ ANN 设计的 -methyleriebisacrylamide(NMBA)and potassiumpersulphate ( KSP )是 AA 是 40.63 ml/L ; AM acted.as 6.25 g/L ; -NMBA 是 1.72 g/Land KSP 是 1.5 g/L , respectively.The PVDFLaizhou SONG Zunju ZHANG Shizhe SONG Zhiming GAO 2007Journal of Materials Science & Technology2007,23,1:2
7Application of fluorescence in situ hybridization in the detection of bladder transitional-cell carcinoma: A multi-center clinical study based on Chinese population显示文摘Objective:To evaluate the diagnostic value of fluorescence in situ hybridization(FISH)in bladder cancer.Methods:We enrolled healthy volunteers and patients who were clinically suspected to have bladder cancer and conducted FISH tests and cytology examinations from August 2007 to December 2008.Receiver operating characteristic(ROC)curve analysis was performed and the area under curve(AUC)values were calculated for both the FISH and urine cytology tests.Results:A cohort of 988 healthy volunteers was enrolled to establish a reference range for the normal population.A total of 4807 patients with hematuria were prospectively,randomly enrolled for the simultaneous analysis of urine cytology,FISH testing,and a final diagnosis as determined by the pathologic findings of a biopsy or a surgically-excised specimen.Overall,the sensitivity of FISH in detecting transitional-cell carcinoma was 82.7%,while that of cytology was 33.4%(p<0.001).The sensitivity values of FISH for non-muscle invasive and muscle invasive bladder transitional-cell carcinoma were 81.7%and 89.6%,respectively(p=0.004).The sensitivity values of FISH for low and high grade bladder cancer were 82.6%and 90.1%,respectively(p=0.002).Conclusion:FISH is significantly more sensitive than voided urine cytology for detecting bladder cancer in patients evaluated for gross hematuria at all cancer grades and stages.Higher sensitivity using FISH was obtained in high grade and muscle invasive tumors.Liqun Zhou Kaiwei Yang Xuesong Li Yi Ding Dawei Mu Hanzhong Li Yong Yan Jinyi Li Dongwen Wang Wei Li Yulong Cong Jiangping Gao Kewei Ma Yajun Xiao Sheng Zhang Hongyi Jiang Weilie Hu Qiang Wei Xunbo Jin Zhichen Guan Qingyong Liu Danfeng Xu Xin Gao Yongguang Jiang Weimin Gan Guang Sun Qing Wang Yanhui Liu Jianquan Hou Liping Xie Xishuang Song Fengshuo Jin Jiafu Feng Ming Cai Zhaozhao Liang Jie Zhang Dingwei Ye Lin Qi Lulin Ma Jianzhong Shou Yuping Dai Jianyong Shao Ye Tian Shizhe Hong Tao Xu Chuize Kong Zefeng Kang Yuexin Liu Xun Qu Benkang Shi Shaobin Zheng Yi Lin Shujie Xia Dong Wei Jianbo Wu Weiling Fu Zhiping Wang Jianbo Liang 2019Asian Journal of Urology2019,6,1:2
8Atmospheric Corrosion Monitoring of Field-exposed Q235B and T91 Steels in Zhoushan Offshore Environment Using Electrochemical Probes显示文摘This work aimed to in-situ monitor the atmospheric corrosion of steels exposed to Zhoushan offshore environment by using electrochemical noise(EN) technique. A portable EN monitoring system was established and two electrochemical probes(named as Q235 B and T91) were designed. Experimental results indicated that the noise resistance of T91 steel was higher than that of Q235 B steel, revealing that the corrosion resistance of T91 was higher than that of Q235 B. A 60-day monitoring result indicated that the noise resistance was well correlated with the weight loss data. Wavelet analyses results of EN data indicated that Q235 B underwent uniform corrosion and T91 suffered from localized corrosion, which was further confirmed by the surface observation. It is concluded that EN can be used as a new method to identify the corrosion form and corrosion resistance in atmospheric conditions.夏大海 SONG Shizhe JIN Weixian LI Jian 高志明 WANG Jihui HU Wenbin 2017Journal of Wuhan University of Technology(Materials Science)2017,32,6:1
9Highly Efficient Heavy-Metal-Ion Removal from Shellfish Processing Liquid with Low Protein and Polysaccharide Loss by Hybrid Mesoporous Silica Diol-APDC-SBA15显示文摘Heavy metal ions in shellfish products are harmful to human health,and their removal with low nutrient loss remains challenging.Herein,a new type of mesoporous silica(SBA15),modified internally with ammonium pyrrolidine dithiocarbamate(APDC)and externally with alkyl-diol groups,which was named as Diol-APDC-SBA15,was successfully developed and characterized by powder X-ray diffraction patterns,nitrogen adsorption,and Fourier transform infrared spectroscopy.The solutions with lead,chromium,cadmium,and copper were used to investigate the adsorption capacity of Diol-APDC-SBA15.Diol-APDC-SBA15 was adopted to remove heavy metals from cooking liquids of clams(Ruditapes philippinarum),hydrolysate liquids of oysters(Ostrea gigas Thunberg),and polysaccharide solution from the cooking liquid of R.philippinarum.The efficiencies of removing heavy metal ions and the loss rates of proteins and polysaccharides were examined.The results showed that the adsorption capacities of Diol-APDCSBA15 for Pb,Cr,Cd,and Cu in standard heavy-metal solutions were 161.4,166.1,29.6,and 60.2mgg^(−1),respectively.The removal efficiency of Diol-APDC-SBA15 for Pb in the three shellfish processing liquids ranged from 60.5%to 99.6%.The Cr removal efficiency was above 99.9%in the oyster hydrolysate liquid.Meanwhile,the percentages of polysaccharide loss were 5.5%and 3.7%in the cooking liquid of clam and polysaccharide solution,respectively,and the protein loss was 1.2%in the oyster hydrolysate liquid.Therefore,the Diol-APDC-SBA15 material exhibits a great potential application in the removal of heavy metals from shellfish processing liquids with low losses of proteins and polysaccharides.QI Yanxia SONG Yang LIU Chang QI Shizhe WANG Haibo CAO Jijuan ZHAO Qiancheng 2023Journal of Ocean University of China2023,22,1:1
10Image analysis of atmospheric corrosion exposure of zinc显示文摘WANG SHOUYAN SONG SHIZHE 2004Materials Science and Engineering2004,,12:1
11Detection of cor- rosion on 304 stainless steel by acoustic emission measure- ment显示文摘Du Gang Wang Weikui Song Shizhe 2010Anti-Corrosion Methods and Materials2010,57,3:1
12Determination of corrosion types from electrochemical noise by phase space reconstruction theory显示文摘Dahai Xia Shizhe Song Jihui Wang Jiangbo Shi Huichao Bi Zhiming Gao 2011Electrochemistry Communications2011,,1:1
13A measurement system based on electrochemical frequency modulation technique for monitoring the early corrosion of mild steel in seawater显示文摘HAN Lei SONG Shizhe 0,,06:1
14显示文摘Song Laizhou Song Shizhe Gao Zhiming 2004Journal of Material Science and Technotohy2004,20,5:1
15Detection of corrosion-induced metal release from tinplate cans using a novel electrochemical sensor and inductively coupled plasma mass spectrometer 显示文摘Dahai Xia Shizhe Song Wenqi Gong 2012Journal of Food Engineering2012,,113:1
16Copper Ions Removal from Wastewater by Electrocoagulation Using Cement-based Cathode Plates显示文摘The present work uses PEO solution to well disperse carbon fiber and identifies percolation thresholds of carbon fiber and carbon black which are used as conductive fillers.The resultant cathode plates have an average compressive strength of 27.3 MPa and flexural strength of 29.09 MPa,which demonstrate excellent mechanical properties.The Cu^(2+)removal efficiency was measured at different current densities in EC process with cement-based cathode plate,while the voltage changes were recorded.The results showed that the cement-based cathode plate operated stably and achieved 99.7%removal of 1 L of simulated wastewater with a Cu^(2+)concentration of 200 ppm at a current density of 8 m A/cm^(2)for 1 h.Characterization of floc and tested cathode plates,SEM and EDS analyses,and repeatability testing of the tested plates demonstrate the reusability of the plates,proving that cement-based plates can effectively replace metal cathode plates,reduce the cost of EC and improve the applicability of EC devices.YOU Song WU Jing WANG Shizhe WANG Wei LI Qiong ZAHNG Ganggang DING Qinjun WANG Luoxin 2023Journal of Wuhan University of Technology(Materials Science)2023,38,2:0
返回顶部 每页显示:
共1页 首页 上一页 第1页 下一页 末页 /1 跳转

网站首页 | 关于我们 | 联系我们 | 产品服务 | 客服中心 | 广告服务 | 版权声明 | 网站联盟 | 友情链接 | 售卡网点

版权所有© 渝B2-20050021-1 渝公网安备 50019002500403号 违法和不良信息举报中心

互联网出版许可证 新出网证(渝)字10号 全国400电话 - 免长途话费