|
|
|
题名
|
作者
|
年代
|
出处
|
被引量
|
| 1 | Stability-improvement Method of Cascaded DC-DC Converters with Additional Voltage-error Mutual Feedback Control显示文摘The interaction between the source and load converters in cascaded DC-DC converters may cause instability.Thus,improving the stability of cascaded DC-DC converters is important.To solve the above-mentioned problem,a flowchart to improve the control method is established by calculating the eigenvalue sensitivity of a time-domain model of cascaded DC-DC converters.Further,an additional voltage-error mutual feedback control method is firstly proposed based on the flowchart provided in this study to improve the stability of cascaded DC-DC converters.Subsequently,the influence of the proposed mutual feedback control on the stability of cascaded DC-DC converters is analyzed.Finally,the effectiveness of the proposed control method is verified by simulation and experiment. | Zhongya Guo Hong Li Chen Liu Yangyang Zhao Wenzhe Su | 2019 | Chinese Journal of Electrical Engineering2019,5,2: | 4 |
| 2 | Further study on anti - inflammatory oxygenated steroids from the oc- tocoral Dendronephthya griffini 显示文摘 | ChaoC H WenZH Su J H | 2008 | Steroids2008,73,14: | 1 |
| 3 | Research and Modeling on the Characteristic Changes of EMI Filter Passive Components under the Influence of Aging显示文摘At present,the power density of power electronic devices in data centers and electric vehicles is constantly increasing,and numerous electronic components are concentrated in a tight,high-temperature environment,which aggravates the performance degradation of electronic components.Consequently,X and Y capacitors,common-mode inductors,and differential-mode inductors used for electromagnetic interference(EMI)suppression suffer from aging effects,and their performance continues to decline.However,the electromagnetic compatibility test is often conducted immediately after the power electronic equipment leaves the factory.The electromagnetic compatibility of power electronic equipment is affected by aging,which is not assessed in current industrial testing.This study conducts aging experiments on passive electronic components in EMI filters and measures the impedance in the frequency range from 150 kHz to 30 MHz.Subsequently,a multi-element aging model based on electromagnetic field analysis is established.The proposed model is suitable for electromagnetic compatibility analysis considering aging.Finally,the aging performance of a commercial two-stage EMI filter is predicted to verify the model proposed in the study.The proposed model explains the degeneration of the EMI filter with aging in the frequency range of 150 kHz to 1 MHz,with a maximum amplitude error of 0.58 dB and phase error of 1.0°. | Wenzhe Su Hong Li Zhichang Yang Baihua Zhang | 2022 | Chinese Journal of Electrical Engineering2022,8,3: | 0 |
| 4 | Simultaneous detection of enterovirus-D68 and vaccine-related poliovirus 3 in the stool samples of a 5-month hospitalized child with acute respiratory disease:A case report显示文摘Human enterovirus(EV)infections can lead to various manifestations,with variable correlations between genotypes and symptoms.Human enterovirus D68(EV-D68)was considered to be associated with acute respiratory disease and acute flaccid myelitis.In this short report,both EV-D68 and poliovirus 3 were detected in the stool of a hospitalized 5-month child who presented with acute respiratory symptoms and who was recently vaccinated with oral polio vaccine(OPV),using a metatranscriptomic high-throughput sequencing method.The nearly full-length genome sequences with complete open reading frames of EV-D68 and poliovirus 3 were assembled.One previously-reported neurovirulence-related amino acid substitution(T860N)in the EV-D68 VP1 region was observed,but the patient showed no neurological symptoms.More attention should be paid to EV-D68,and continuous multiple syndrome-based surveillance on non-polio enterovirus is called for. | Wenzhe Su Qing Zeng Jinmei Geng Jingwen Liu Huaping Xie Kuibiao Li Pengzhe Qin Chaojun Xie Biao Di | 2023 | Biosafety and Health2023,5,4: | 0 |
| 5 | Spatio-temporal Evolution Characteristics and Driving Forces of Winter Urban Heat Island:A Case Study of Rapid Urbanization Area of Fuzhou City,China显示文摘Under the influence of anthropogenic and climate change,the problems caused by urban heat island(UHI)has become increasingly prominent.In order to promote urban sustainable development and improve the quality of human settlements,it is significant for exploring the evolution characteristics of urban thermal environment and analyzing its driving forces.Taking the Landsat series images as the basic data sources,the winter land surface temperature(LST)of the rapid urbanization area of Fuzhou City in China was quantitatively retrieved from 2001 to 2021.Combing comprehensively the standard deviation ellipse model,profile analysis and GeoDetector model,the spatio-temporal evolution characteristics and influencing factors of the winter urban thermal environment were systematically analyzed.The results showed that the winter LST presented an increasing trend in the study area during 2001–2021,and the winter LST of the central urban regions was significantly higher than the suburbs.There was a strong UHI effect from 2001 to 2021with an expansion trend from the central urban regions to the suburbs and coastal areas in space scale.The LST of green lands and wetlands are significantly lower than croplands,artificial surface and unvegetated lands.Vegetation and water bodies had a significant mitigation effect on UHI,especially in the micro-scale.The winter UHI had been jointly driven by the underlying surface and socio-economic factors in a nonlinear or two-factor interactive enhancement mode,and socio-economic factors had played a leading role.This research could provide data support and decision-making references for rationally planning urban layout and promoting sustainable urban development. | WANG Zili LU Chunyan SU Yanlin SU Yue YU Qianru LI Wenzhe YANG Nuocheng | 2024 | Chinese Geographical Science2024,34,1: | 0 |