维普中文期刊产品整合服务
2篇 您的检索式:作者名="Folan Li"
    题名 作者 年代 出处 被引量
1Correlation between Vascular Calcification and Serum Sclerostin in MHD Patients显示文摘Objective Investigate the correlation between serum sclerostinlevel and chronic kidney disease-mineral and bone disorder(CKD-MBD),especially vascular calcification,in maintenance hemodialysis(MHD)patients.Methods This is across-sectional study,a total of 72 MHD patients were included from the first affiliated hospital of Jinan university.Measure the biochemical indicators of mineral metabolism,renal function,and serum sclerostin level by ELISA.The abdominal aorta calcification score(AACS)was assessed according to Kauppila method on lateral spine imaging using DEXA.Patients were distributed into two groups according to the level of serum sclerostin:low sclerostingroup(≤125 pg/ml)and high sclerostingroup(>125 pg/ml).Analyze the association of serum sclerostin level with the indicators of CKD-MBD.Results There was significant difference in i PTH level between high sclerost in group and low sclerost in group.Multivariate Logistic regression analysis demonstrated that dialysis duration,male and anuria were independent risk factor of high sclerostin level,and i PTH and Kt/V were protective factors.Conclusion Dialysis duration,man,anuria was independent risk factors and i PTH,Kt/V were protective factors of high serum sclerostin level in MHD patients.There was no correlation between abdominal aorta calcification and serum sclerostin level.Yangyang Zhang Shufei Zeng Chen Yun Lifeng Yang Fanna Liu Guanmin Wu Taksui Wong Bo Hu Xiangnan Dong Folan Li Yu Chen Peitian Yang Aiyun Cha Huanhuan Liu Mingming Ma B.Hocher W. Pommer Huiyuan Zheng Tong Liu Zuhui Chen Lianghong Yin 2017临床医学工程2017,24,S1:0
2Analysis of Performance Stability and Clinical Efficacy of OBERS - 3000 Hemodialysis Machine显示文摘Objective To explore the method of safety and efficacy validation of hemodialysis machine,and observe the clinical efficacy of OBERS-3000 multifunctional hemodialysis machine.Methods Randomized,open,two-phase crossover and positive control design,a total of 72 patients from two hospitals were included.OBERS-3000 multifunctional hemodialysis machine was the test machine,and the Fresenius 4008 series hemodialysis machine was as the control machine,indicators of blood routine test,serum electrolytes,liver and kidney function test,blood gas analysis,CRP were compared,body weight before and after hemodialysis,ultrafiltration volume were recorded,urea clearance index,urea reduction ratio were calculated.The XL90 conductivity meter was connected in series in the test machine,to monitor the temperature,conductance,venous pressure and arterial pressure during the dialysis in real time,and the measured value were compared with the machine monitoring value.Results Both of the test machine and the control machine could effectively eliminate creatinine,urea nitrogen and other uremic toxins,could continuously supply qualified dialysate,and precisely control the ultrafiltration volume.There were no significant differences in temperature,conductance,venous pressure and arterial pressure monitoring with the real time measured value by XL90 conductivity meter.Conclusions OBERS-3000 multifunctional hemodialysis machine can effectively eliminate uremic toxins,maintain electrolyte and acid-base balance,and can accurately display the monitoring parameters.Lianghong Yin Bo Hu Lihua Luo Lifeng Yang Guanmin Wu Liangyong Hu Fanna Liu Yu Chen Peitian Yang Long Xiao Huiyuan Zheng Tong Liu Hongwei Hu Chen Yun Ying Huang Xia Yu Folan Li Aiyun Cha Xiangnan Dong Huanhuan Liu Mingming Ma Yongpin Lu Taksui Wong Baozhang Guan Yingming Gu Zuhui Chen 2017临床医学工程2017,24,S1:0
返回顶部 每页显示:
共1页 首页 上一页 第1页 下一页 末页 /1 跳转

网站首页 | 关于我们 | 联系我们 | 产品服务 | 客服中心 | 广告服务 | 版权声明 | 网站联盟 | 友情链接 | 售卡网点

版权所有© 渝B2-20050021-1 渝公网安备 50019002500403号 违法和不良信息举报中心

互联网出版许可证 新出网证(渝)字10号 全国400电话 - 免长途话费