|
|
|
题名
|
作者
|
年代
|
出处
|
被引量
|
| 1 | 0.04 degree-per-hour MEMS disk resonator gyroscope with high-quality factor (510 k) and long decaying time constant(74.9 s)显示文摘The disk resonator gyroscope is an attractive candidate for high-performance MEMS gyroscopes.This gyroscope consists of a sensor and readout electronics,and the characteristics of the sensor directly determine the performance.For the sensor,a high-quality factor and long decaying time constant are the most important characteristics required to achieve high performance.We report a disk resonator gyroscope with a measured quality factor of 510 k and decaying time constant of 74.9 s,which is a record for MEMS silicon disk resonator gyroscopes,to the best of our knowledge.To improve the quality factor of the DRG,the quality factor improvement mechanism is first analyzed,and based on this mechanism two stiffness-mass decoupled methods,i.e.,spoke length distribution optimization and lumped mass configuration design,are proposed and demonstrated.A disk resonator gyroscope prototype is fabricated based on these design strategies,and the sensor itself shows an angle random walk as low as 0.001°/√h,demonstrating true potential to achieve navigation-grade performance.The gyroscope with readout electronics shows an angle random walk of 0.01°/√h and a bias instability of 0.04°/h at room temperature without compensation,revealing that the performance of the gyroscope is severely limited by the readout electronics,which should be further improved.We expect that the quality factor improvement methods can be used in the design of other MEMS gyroscopes and that the newly designed DRG can be further improved to achieve navigation-grade performances for high-end industrial,transportation,aerospace,and automotive applications. | Qingsong Li Dingbang Xiao Xin Zhou Yi Xu Ming Zhuo Zhanqiang Hou Kaixuan He Yongmeng Zhang Xuezhong Wu | 2018 | Microsystems & Nanoengineering2018,4,1: | 16 |
| 2 | The electromagnetic wave experiment for CSES mission: Search coil magnetometer显示文摘The seismic activities on the Earth can produce a disturbance of the electromagnetic field and particles in the ionosphere. The search coil magnetometer(SCM) mounted on China Seismo-Electromagnetic satellite(CSES) is designed to measure the magnetic field fluctuation of low frequency electromagnetic waves in the frequency range of 10 Hz–20 k Hz. The SCM comprises a three-axis search coil sensor mounted on a 4.5 m boom and an electronic box inside satellite module. The sampling rate of the SCM is 51.2 k Hz and the time resolution of the power spectrum density(PSD) is 2 s. The frequency resolution is 12.5 Hz.There are three operation modes: survey, detailed survey and calibration. In the survey mode, the SCM can provide a PSD in the whole frequency range of 10 Hz–20 k Hz and wave forms in the low frequency range below 2 k Hz while in the detailed survey mode the SCM can provide both PSD and wave forms in the whole frequency range of 10 Hz–20 k Hz. The sensitivity of the SCM instrument is 5.0×10^(-4) n T Hz^(-1/2) at 10 Hz, 5.0×10^(–5) n T Hz^(-1/2) at 200 Hz, 3.4×10^(-5) n T Hz^(-1/2) at 2 k Hz and 1.1×10^(-4) n T Hz^(-1/2) at 20 k Hz. The telemetry rate is ~0.85 Mbps in the survey mode and ~3.0 Mbps in the detailed survey mode. The phase difference between three axes can be made generally with a precision of less than 1.0°. The dynamic range of the SCM instrument is over 100 d B. The orthogonality of three mechanical axes of search coil senor is better than 0.13°. The performance of SCM can satisfy the requirement of scientific objectives of CSES mission. | CAO JinBin ZENG Li ZHAN Feng WANG ZuoGui WANG Yan CHEN Yu MENG QingChun JI ZhanQiang WANG PengFei LIU ZhongWei MA LingYu | 2018 | Science China(Technological Sciences)2018,61,5: | 13 |
| 3 | High wall-plug efficiency 808-nm laser diodes with a power up to 30.1 W显示文摘A very highly efficient InGaAlAs/AlGaAs quantum-well structure was designed for 808 nm emission,and laser diode chips 390-μm-wide aperture and 2-mm-long cavity length were fabricated.Special pretreatment and passivation for the chip facets were performed to achieve improved reliability performance.The laser chips were p-side-down mounted on the AlN submount,and then tested at continuous wave(CW)operation with the heat-sink temperature setting to 25℃using a thermoelectric cooler(TEC).As high as 60.5%of the wall-plug efficiency(WPE)was achieved at the injection current of 11 A.The maximum output power of 30.1 W was obtained at 29.5 A when the TEC temperature was set to 12°C.Accelerated life-time test showed that the laser diodes had lifetimes of over 62111 h operating at rated power of 10 W. | Zhanqiang Ren Qingmin Li Bo Li Kechang Song | 2020 | Journal of Semiconductors2020,41,3: | 3 |
| 4 | Hybrid bound states in the continuum in terahertz metasurfaces显示文摘Bound states in the continuum(BICs)have exhibited extraordinary properties in photonics for enhanced light-matter interactions that enable appealing applications in nonlinear optics,biosensors,and ultrafast optical switches.The most common strategy to apply BICs in a metasurface is by breaking symmetry of resonators in the uniform array that leaks the otherwise uncoupled mode to free space and exhibits an inverse quadratic relationship between quality factor(Q)and asymmetry.Here,we propose a scheme to further reduce scattering losses and improve the robustness of symmetry-protected BICs by decreasing the radiation density with a hybrid BIC lattice.We observe a significant increase of radiative Q in the hybrid lattice compared to the uniform lattice with a factor larger than 14.6.In the hybrid BIC lattice,modes are transferred toГpoint inherited from high symmetric X,Y,and M points in the Brillouin zone that reveal as multiple Fano resonances in the far field and would find applications in hyperspectral sensing.This work initiates a novel and generalized path toward reducing scattering losses and improving the robustness of BICs in terms of lattice engineering that would release the rigid requirements of fabrication accuracy and benefit applications of photonics and optoelectronic devices. | Junxing Fan Zuolong Li Zhanqiang Xue Hongyang Xing Dan Lu Guizhen Xu Jianqiang Gu Jiaguang Han Longqing Cong | 2023 | Opto-Electronic Science2023,2,4: | 1 |
| 5 | Multiscale design and biomechanical evaluation of porous spinal fusion cage to realize specified mechanical properties显示文摘Backgrou nd Dense titanium(Ti)fusion cages have been commonly used in transforaminal lumbar interbody fusion.However,the stiffness mismatch between cages and adjacent bone endplates increases the risk of stress shielding and cage subsidence.Methods The current study presents a multiscale optimization approach for porous Ti fusion cage development,including microscale topology optimization based on homogenization theory that obtains a unit cell with prescribed mechanical properties,and macroscale topology optimization that determines the layout of framework structure over the porous cage while maintaining the desired stiffness.The biomechanical performance of the designed porous cage is assessed using numerical simulations of fusion surgery.Selective laser melting is employed to assists with fabricating the designed porous structure and porous cage.Results The simulations demonstrate that the designed porous cage increases the strain energy density of bone grafts and decreases the peak stress on bone endplates.The mechanical and morphological discrepancies between the as-designed and fabricated porous structures are also described.Conclusion From the perspective of biomechanics,it is demonstrated that the designed porous cage contributes to reducing the risk of stress shielding and cage subsidence.The optimization of processing parameters and post-treatments are required to fabricate the designed porous cage.The present multiscale optimization approach can be extended to the development of cages with other shapes or materials and further types of orthopedic implants. | Hongwei Wang Yi Wan Quhao Li Xinyu Liu Mingzhi Yu Xiao Zhang Yan Xia Qidong Sun Zhanqiang Liu | 2022 | Bio-Design and Manufacturing2022,5,2: | 1 |
| 6 | Microstructure and grain abrasion properties of TiC-xNi coatings prepared by electro-thermal explosion ultra-high speed spraying显示文摘 | Liu Zongde Li Bin Wang Zhanqiang | | 0,,: | 1 |
| 7 | High-entropy(Sm_(0.2)Eu_(0.2)Gd_(0.2)Dy_(0.2)Er_(0.2))_(2)Hf_(2)O_(7) ceramic with superb resistance to radiation-induced amorphization显示文摘Nuclear engineering materials are required to possess outstanding extreme environmental tolerance and irradiation resistance.A promising novel pyrochlore-type of(Sm_(0.2)Eu_(0.2)Gd_(0.2)Dy_(0.2)Er_(0.2))2 Hf_(2)O_(7)high-entropy ceramic(HE-RE2 Hf_(2)O_(7))for control rod was prepared by solid-state reaction method.The ion irradiation of HE-RE_(2) Hf_(2)O_(7)with 400 keV Kr+at 400℃was investigated using a 400 kV ion implanter and compared with single-component pyrochlore Gd2 Hf_(2)O_(7)to evaluate the irradiation resistance.For HE-RE2 Hf_(2)O_(7),the phase transition from pyrochlore to defective fluorite is revealed after irradiation at 60 dpa.After irradiation at 120 dpa,it maintained crystalline,which is comparable to Gd2 Hf_(2)O_(7)but superior to the titanate pyrochlores previously studied.Moreover,the lattice expansion of HE-RE2 Hf_(2)O_(7)(_(0.2)2%)is much lower than that of Gd2 Hf_(2)O_(7)(0.62%),indicating excellent irradiation damage resistance.Nanoindentation tests displayed an irradiation-induced increase in hardness and a decrease in elastic modulus by about 2.6%.Irradiation-induced segregation of elements is observed on the surface of irradiated samples.In addition,HE-RE2 Hf_(2)O_(7)demonstrates a more sluggish grain growth rate than Gd2 Hf_(2)O_(7)at 1200℃,suggesting better high-temperature stability.The linear thermal expansion coefficient of HE-RE2 Hf_(2)O_(7)is 10.7×10-6 K-1 at 298–1273 K.In general,it provides a new strategy for the design of the next advanced nuclear engineering materials. | Jingxin Wu Meng Zhang Zhanqiang Li Minzhong Huang Huiming Xiang Liyan Xue Zhengming Jiang Zhigang Zhao Lianfeng Wei Yong Zheng Fan Yang Guang Ran Yanchun Zhou Heng Chen | 2023 | Journal of Materials Science & Technology2023,,24: | 1 |
| 8 | Design of cooling water scheme of gas compressing station in west-to-east gas pipeline 显示文摘 | Li Hongtao Xu Zhanqiang Zhu Benrui | 2014 | Applied Mechanics and Materials2014,577,: | 1 |
| 9 | Efficiency Enhancement of Cu(In,Ga)Se_2 Solar Cells by Applying SiO_2-PEG/PVP Antire flection Coatings显示文摘An effective approach was presented to enhance photoelectric conversion efficiency of Cu(In,Ga)Se2 (CIGS) solar cells by using modified SiO2 antireflection coatings(ARCs) to harvest more incident sunlight.Polyethylene glycol(PEG) and polyvinyl pyrrolidone(PVP) used as additives were introduced into silica sols to prepare SiO2-PEG and SiO2-PVP coatings in the sol-gel dip-coating process,respectively. The different effects of PEG and PVP additives on SiO2 coatings were analyzed and the antireflection performance of SiO2-PEG and SiO2-PVP coatings was investigated. The transmittance over 97% ranging from 450 nm to 700 nm with a maximum transmittance over 99.40% at about 550 nm was achieved for both SiO2-PEG2000A and SiO2-PVP0.5 coatings. The relative efficiencies of CIGS solar cells coated with SiO2-PEG2000A and SiO2-PVP0.5 ARCs were increased by 7.27% and 8.33%,respectively. The modified SiO2 ARCs possessed the advantages of the low manufacturing cost,good adhesion,superior antireflective performance and the feasible method for large area fabrication. | Dezeng Li Zhanqiang Liu Yaoming Wang Yongkui Shan Fuqiang Huang | 2015 | Journal of Materials Science & Technology2015,31,2: | 0 |